20
Harrier GTE -
Installation & Servicing
INSTALLATION
28 ASSEMBLING THE FLOW, RETURN AND DRAIN COCK
har7005
1
1
2
2
2
1
2
Drain cock
GTE 5
GTE 6
GTE 7
GTE 8
GTE 9
Tightness sealant
(not supplied)
Plumb
Line
=
=
fal7006
3
1. Coat the threaded and tapped connections of the
sections, pipes and drain cock with thread
sealing tape or compound (not supplied).
2. Screw the flow and return pipes and the drain
cock into the rear section. (Ensure the tapping on
the flow connection faces upwards to accept the
pressure relief valve.)
Note.
This tapping is not to be used for venting.
3. Use plumbline to ensure the flanges are vertical
and equally screwed into the tappings.
INST
ALLA
TION