CAUTION

To protect yourself, think "Safety First":
• Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution.
• Use appropriate personal protective equipment such as safety glasses, face

shields, insulating gloves, insulating boots, and/or insulating mats.

• Before each use:

-

Perform a continuity test by touching the test leads together to verify the 
functionality of the battery and test leads.

-

Use the 3 Point Safety Method.  (1) Verify meter operation by measuring a 
known voltage.  (2) Apply meter to circuit under test.  (3) Return to the 
known live voltage again to ensure proper operation.

• Never ground yourself when taking electrical measurements.
• Connect the black common lead to ground or neutral before applying the red

test lead to potential voltage.  Disconnect the red test lead from the voltage
first.

• Always work with a partner.
• When using the probes, keep fingers as far behind the probe tips as possible.

Features: 

• Auto/manual ranging clamp meter
• Non-Contact Voltage (70-600VAC)
• Measures 400 AAC Current
• Measures AC/DC Voltage and Resistance
• Audible continuity
• Data hold
• Auto Power Off
• Low Battery Indicator
• Compact jaws for reaching into tight spaces
• Electronic overload protection on all ranges

• 61-732 model is averaging sensing, rms calibrated
• 61-736 model is true rms sensing.

ND 4952-1 61-732/736 Instructio  9/2/04  9:41 AM  Page 3

Summary of Contents for 61-732

Page 1: ...61 732 61 736 400 AAC Clamp Meter Instruction Manual HOLD APO K M m V A AC DC...

Page 2: ...ecurely in place Inspect and replace leads if insulation is damaged metal is exposed or probes are cracked Pay particular attention to the insulation surrounding the connectors Do not use meter if it...

Page 3: ...wn live voltage again to ensure proper operation Never ground yourself when taking electrical measurements Connect the black common lead to ground or neutral before applying the red test lead to poten...

Page 4: ...11 4000 count display 12 Units of measure 13 Voltage 14 Amperes 15 Ohms 16 Continuity 17 AC measurement is selected 18 DC measurement is selected 19 Polarity indicator for DC 20 Low battery indicator...

Page 5: ...auto ranging feature of the meter A appears in the upper left side of the display Continue pressing the Range button until the desired range is obtained Use this mode to lock in a specific range for r...

Page 6: ...Page 6 CORRECT Use with line splitter INCORRECT Currents cancel CORRECT Single Conductor only AC Voltage DC Voltage Measuring AC Current Amps Measuring Voltage H N...

Page 7: ...ergized The meter will sense the level of resistance and beep if the resistance is less than 25 to confirm that continuity is present Closed Circuit Open Circuit Measuring Resistance Ohms Verify the c...

Page 8: ...ies with two AAA batteries Assemble the battery cap to the meter and re tighten the screws Maintenance Clean the case with a damp cloth and mild detergent Do not use abrasives or solvents Service and...

Page 9: ...R H Temperature 0 1 x specified accuracy per C Coefficient 0 C to 18 C 28 C to 50 C Altitude 6561 7 ft 2000m Operating Environment 32 F to 122 F 0 C to 50 C at 70 R H Storage Environment 4 F to 140 F...

Page 10: ...400 0k Resistance 4 000M 1 5 4 digits 600 VDC or AC rms 40 00M 3 0 5 digits Continuity Audible indication 25 N A 600 VDC or AC rms Response time 500ms Ranges Accuracies AC Converter 61 732 model is av...

Page 11: ...ng out of the sale of an IDEAL product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above The manufacturer shall not be li...

Reviews: