IDEAL 61-732 Instruction Manual Download Page 5

Page 5

OPERATION:
Non-contact voltage (NCV) 

With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV but-
ton. The NCV LED will light and the beeper will sound. The closer the NCV tab is to
AC voltage, the louder the beep. To differentiate between hot and neutral in an outlet,
insert the NCV tab into each slot in the outlet.  The beeper will be much louder on
the hot side of the outlet than the neutral.  The test lead can also be used to differen-
tiate between the hot and neutral.  Plug the red test lead into the V/

input jack on

the meter.  Press the NCV button and insert the probe tip into each slot of the outlet.
The beeper will only beep on the hot side of the outlet.

Auto/Manual Ranging Mode 

(     )

The meter defaults to autoranging mode when powered on.  In this mode, the meter
automatically selects the best range to display the measurement.  By pressing the
Range (     ) button on the meter, the manual range mode will override the auto-
ranging feature of the meter.  A (     ) appears in the upper left side of the display.
Continue pressing the Range button until the desired range is obtained.  Use this
mode to lock in a specific range for repeated measurements.  To return to the
autoranging mode, either depress the Range button for greater than 1 second or turn
the meter off and then back on again.

Data Hold Feature

Press the Hold button on the side of the meter to toggle in and out of the data hold
mode.  “HOLD” appears in the upper left of the meter display when data hold is
active.  Use the data hold feature to lock a measurement reading on the display.
Press the Hold button again to unlock the display and obtain a real-time reading.

Auto Power Off (APO) Feature

The meter automatically powers itself down after about 10 minutes of no use.  Press
any button, and the meter will wake up and display the last reading taken before
power down.  This feature can be overridden by holding the Range (     ) button
while turning the function switch from Off to any other position.  When APO is
defeated, the “APO” will be removed from the display. Turning the meter off will
restore the APO default.

ND 4952-1 61-732/736 Instructio  9/2/04  9:41 AM  Page 5

Summary of Contents for 61-732

Page 1: ...61 732 61 736 400 AAC Clamp Meter Instruction Manual HOLD APO K M m V A AC DC...

Page 2: ...ecurely in place Inspect and replace leads if insulation is damaged metal is exposed or probes are cracked Pay particular attention to the insulation surrounding the connectors Do not use meter if it...

Page 3: ...wn live voltage again to ensure proper operation Never ground yourself when taking electrical measurements Connect the black common lead to ground or neutral before applying the red test lead to poten...

Page 4: ...11 4000 count display 12 Units of measure 13 Voltage 14 Amperes 15 Ohms 16 Continuity 17 AC measurement is selected 18 DC measurement is selected 19 Polarity indicator for DC 20 Low battery indicator...

Page 5: ...auto ranging feature of the meter A appears in the upper left side of the display Continue pressing the Range button until the desired range is obtained Use this mode to lock in a specific range for r...

Page 6: ...Page 6 CORRECT Use with line splitter INCORRECT Currents cancel CORRECT Single Conductor only AC Voltage DC Voltage Measuring AC Current Amps Measuring Voltage H N...

Page 7: ...ergized The meter will sense the level of resistance and beep if the resistance is less than 25 to confirm that continuity is present Closed Circuit Open Circuit Measuring Resistance Ohms Verify the c...

Page 8: ...ies with two AAA batteries Assemble the battery cap to the meter and re tighten the screws Maintenance Clean the case with a damp cloth and mild detergent Do not use abrasives or solvents Service and...

Page 9: ...R H Temperature 0 1 x specified accuracy per C Coefficient 0 C to 18 C 28 C to 50 C Altitude 6561 7 ft 2000m Operating Environment 32 F to 122 F 0 C to 50 C at 70 R H Storage Environment 4 F to 140 F...

Page 10: ...400 0k Resistance 4 000M 1 5 4 digits 600 VDC or AC rms 40 00M 3 0 5 digits Continuity Audible indication 25 N A 600 VDC or AC rms Response time 500ms Ranges Accuracies AC Converter 61 732 model is av...

Page 11: ...ng out of the sale of an IDEAL product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above The manufacturer shall not be li...