WARNING

Read First:  Safety Information

Understand and follow operating instructions carefully.  Use the meter only as
specified in this manual; otherwise, the protection provided by the meter may be
impaired.

WARNING

To avoid possible electric shock, personal injury or death, follow these
guidelines:

• Do not use if meter appears damaged.  Visually inspect the meter to ensure

case is not cracked and back case is securely in place.

• Inspect and replace leads if insulation is damaged, metal is exposed, or probes

are cracked.  Pay particular attention to the insulation surrounding the
connectors.

• Do not use meter if it operates abnormally as protection maybe impaired.  
• Do not use during electrical storms or in wet weather.
• Do not use around explosive gas, dust, or vapor.
• Do not apply more than the rated voltage to the meter. 
• Do not use without the battery and the back case properly installed.
• Remove the test leads from the circuit prior to removing battery cap.
• Do not attempt to repair this unit as it has no user-serviceable parts.

ND 4952-1 61-732/736 Instructio  9/2/04  9:41 AM  Page 2

Summary of Contents for 61-732

Page 1: ...61 732 61 736 400 AAC Clamp Meter Instruction Manual HOLD APO K M m V A AC DC...

Page 2: ...ecurely in place Inspect and replace leads if insulation is damaged metal is exposed or probes are cracked Pay particular attention to the insulation surrounding the connectors Do not use meter if it...

Page 3: ...wn live voltage again to ensure proper operation Never ground yourself when taking electrical measurements Connect the black common lead to ground or neutral before applying the red test lead to poten...

Page 4: ...11 4000 count display 12 Units of measure 13 Voltage 14 Amperes 15 Ohms 16 Continuity 17 AC measurement is selected 18 DC measurement is selected 19 Polarity indicator for DC 20 Low battery indicator...

Page 5: ...auto ranging feature of the meter A appears in the upper left side of the display Continue pressing the Range button until the desired range is obtained Use this mode to lock in a specific range for r...

Page 6: ...Page 6 CORRECT Use with line splitter INCORRECT Currents cancel CORRECT Single Conductor only AC Voltage DC Voltage Measuring AC Current Amps Measuring Voltage H N...

Page 7: ...ergized The meter will sense the level of resistance and beep if the resistance is less than 25 to confirm that continuity is present Closed Circuit Open Circuit Measuring Resistance Ohms Verify the c...

Page 8: ...ies with two AAA batteries Assemble the battery cap to the meter and re tighten the screws Maintenance Clean the case with a damp cloth and mild detergent Do not use abrasives or solvents Service and...

Page 9: ...R H Temperature 0 1 x specified accuracy per C Coefficient 0 C to 18 C 28 C to 50 C Altitude 6561 7 ft 2000m Operating Environment 32 F to 122 F 0 C to 50 C at 70 R H Storage Environment 4 F to 140 F...

Page 10: ...400 0k Resistance 4 000M 1 5 4 digits 600 VDC or AC rms 40 00M 3 0 5 digits Continuity Audible indication 25 N A 600 VDC or AC rms Response time 500ms Ranges Accuracies AC Converter 61 732 model is av...

Page 11: ...ng out of the sale of an IDEAL product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above The manufacturer shall not be li...

Reviews: