Specifications:
Display:
3-3/4 digit LCD with 4000 counts
Polarity:
Automatic, positive implied, negative (-) polarity indication.
Overrange:
"OL" indication is displayed.
Measure Rate:
Samples 2 times per second, nominal.
Auto Power Off:
Approximately after 10 minutes of non-use.
Battery Life:
400 hours continuous with Alkaline (61-732)
250 hours continuous with Alkaline (61-736)
Low Battery Indication: The " " is displayed when battery voltage drops below
operating level.
Power Supply:
(2) 1.5V "AAA" batteries (NEDA R03).
Includes an isolated battery compartment.
Accuracy:
Stated accuracy at 23°C ±5°C, <75% R.H.
Temperature
0.1 x (specified accuracy) per °C,
Coefficient:
(0°C to 18°C, 28°C to 50°C).
Altitude:
6561.7 ft. (2000m)
Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% R.H.
Storage Environment: -4°F to 140°F (-20°C to 60°C) at < 80% R.H.
Jaw Opening:
Accepts a 1.25" (32mm) conductor
Dimensions:
7.4"H x2.6"W x1.5"D (187mm H x65mm W x37mm D)
Weight:
6.7 oz (190g) including batteries
Accessories included:
Carrying Case, Test Leads, (2) 1.5V "AAA" batteries,
operating instructions.
Safety:
Complies with EN 61010-1, EN 61010-2-032, UL 61010B-1,
UL 61010B-2-032 specifications, Clamp rated to
Cat III-300V. Voltage rated for Cat III-600V.
Double Insulation
Instrument has been evaluated and complies with insulation category II (overvoltage
category II). Pollution degree 2 in accordance with IEC-644. Indoor use.
+
C
US
N12966