![IDEAL 61-732 Instruction Manual Download Page 10](http://html2.mh-extra.com/html/ideal/61-732/61-732_instruction-manual_3675112010.webp)
Page 10
Accuracy
Function
Range and
Overload
Resolution
61-732
61-736
Protection
AC Current*
40.0A/400.0A
(50Hz - 60Hz)
1.7% + 6 digits 1.7% + 10 digits
400AAC
40.0A/400.0A
(60Hz - 400Hz)
3.0% + 6 digits 3.0% + 10 digits
AC Voltage
400.0V
(50Hz - 500Hz)
1.2% + 5 digits 1.2% + 8 digits
600 VDC or AC rms
600V
(50Hz - 500Hz)
1.5% + 5 digits 1.5% + 8 digits
DC Voltage 400.0V/600V
0.5% + 2 digits
600 VDC or AC rms
400.0
Ω
/4.000k
Ω
/40.00k
Ω
/
1.0% + 4 digits
400.0k
Ω
Resistance
4.000M
Ω
1.5% + 4 digits
600 VDC or AC rms
40.00M
Ω
3.0% + 5 digits
Continuity
Audible indication < 25
Ω
N/A
600 VDC or AC rms
Response time: 500ms
Ranges & Accuracies:
AC Converter:
61-732 model is averaging sensing, rms calibrated
61-736 model is true rms sensing.
Accuracy:
Accuracy is specified as +/-(a percentage of the r a fixed amount) at
23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity.
Temperature Coefficient:
0.1 times the applicable accuracy specification per
degree C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F)
* Accuracy stated for crest factor
≤
3
Input Impedance is 10M
Ω
.
ND 4952-1 61-732/736 Instructio 9/2/04 9:41 AM Page 10