The appliance must be connected correctly to the mains power supply, i.e. to the terminals marked L (line),
N (Neutral) , otherwise correct operation cannot be assured.
UK
The appliance must be installed by qualified personnel in compliance with current regulations and regulations in place
relative to domestic electrical wiring and plumbing.
The luminaries must be installed in dedicated rooms and must NOT be installed outdoors.
ECOLOGICAL NOTES
Upon completion of the installation phase, please remember to dispose of the packaging and assembly
scraps in accordance with standards in effect in the country where the product will be used.
In order to ensure correct installation and maintenance
of the product, the manufacturer recommends careful
attention to the instructions contained in this
manual.
Compliance with safety norms and the
suggestions described in this manual will ensure that
the product functions perfectly and that the manufacturer’s
warranty will be fully applicable.
P
RECAUTIONS
A person who is capable of demonstrating to pertinent
authorities that he has the knowledge and skill in the
application of national regulatory requirements concerning
safety, i.e. electricity, water supply, and disposal.
I
NSTALLER
The installer is responsible for the choice of materials and
complying with standards and laws:
- He must not tamper with the electrical parts of the product, he
must limit himself to connecting and installing
the components as explained in this manual.
- He must guarantee that the work done will not compromise
the IP protection level of the luminaries components.
-
If the external flexible cable or cord of this luminaire is
damaged, it shall be exclusively replaced by the manu-
facturer or his service agent or a similar qualified person
in order to avoid a hazard.
- To connect the unit to the fixed lighting is necessary to use
a terminal conforming to EN 60998-2-1.
The terminal must be screw Bipolar (L, N), 1.5 mm ², 230 V ~, IP44;
- In the case of a failure or malfunction he must contact
After-Sales Service who will supply original spare parts.
The manufacturer is not liable if the product is installed on
premises where the structures and systems are not to
standard or for work performed by unqualified
or unskilled personnel.
The electrical specification of the product with the CE
mark and relative rating plate values are given on the
label on back of the product.Under on circum
stances must this label be removed.
I
NSTALLATION
Before you start installation it is advisable to:
- check the integrity of the packaging as indicated on the
pack;
- check that the product has not received blows or
been tampered with.
Once the product is installed, the manufacturer cannot
be held liable for any of the damage mentioned above.
P
RE
-
INSTALLATION CHECKS
Safety distances and clearances
Zone 0
Zone 2
Zone 3
Zone 1
Prior to installation, check that the electrical system is
compliant with standards and laws in effect and that it is
equipped with a magneto-thermal differential switch with
an adequate breaking capacity and a differential of 30mA.
Connection must be made in a fixed and permanent
manner, with no intermediate connections, by installing
an adequate omnipolar disconnecting switch with
minimum aperture distance of contacts which allows
complete disconnection in conditions of category III,
outside of zones 0-1-2-3 and protected from water splash-
es (60 cm laterally beyond the side of the tub or at height
of 225 cm from the floor). (fig. 1)
The power cable must be protected inside the wall by a
corrugated tube or by another system that is compliant
with current standards and certified by the CE directive up
to the connector.