Ecomod Heat Pump Control -
Installation and Servicing
8.5.2.1. Relay output QX*
Line no.
Programming
Possible values
QX1
QX2
QX3
QX4
QX5
5890
5891
5892
5894
5895
Relay output QX1, 2, 3, 4, 5
None | Consumption circuit pump
1 Q15 | Consumption circuit pump
2 Q15 | Pool circuit pump Q19 |
Heating circuit 3 pump Q20 | Alarm
output K10 | Timer programme 5
K13 | Heating circuit 1 pump Q2
| DHW pump/valve Q3 | Stage
1 compressor K1 | Raise gen.
regulation K32 | Heating circuit 2
pump Q6 | Regulator dT 1 K21 |
Regulator dT 2 K22 |
The output settings assign the corresponding functions based on the selection.
By default, relay QX1 is configured for remote fault reporting.
None
No function on the relay output.
Consumption circuit pump 1 Q15
Function not available
.
Alarm output K10
If a fault occurs it is reported by the alarm relay. Contact closure has a two minute
delay time. Once the error is eliminated, i.e. the error message is no longer present, the
contact opens immediately.
Note: If the fault cannot be eliminated for now, the relay can still be reset. This is
done from the
Faults
page.
Pump CC3 Q20
Function not available.
Consumption circuit pump 2 Q15
Function not available
.
Pump CC1 Q2
Function not available
.
Pump CC2 Q6
Function not available
.
DHW pump/valve Q3
The relay controls the activation of the W3100 hydraulic station
Temp. change regulator 1 K21 / Temp. change regulator 1 K22
Relays K21 and K22 are used by the temperature change regulator dT.
Pool circuit pump Q19
Function not available
.
Condenser pump Q9
Function not available.
8.5.2. Configuring Ecomod Heat Pump Control inputs / outputs
* = restricted access leve
l