![Ideal Heating ECOMOD HEAT PUMP CONTROL Installation And Servicing Download Page 32](http://html1.mh-extra.com/html/ideal-heating/ecomod-heat-pump-control/ecomod-heat-pump-control_installation-and-servicing_3612612032.webp)
Page 32 / 86
00U07310090-A
Ecomod Heat Pump Control -
Installation and Servicing
8.1.3.1. Time programme (DHW circuits)
Line no.
Programming
Possible values
DHW
560
Preselection
Mon-Sun | Mon-Fri | Sat-Sun |
Mon…Sunday
561
1st period start time
00:00 … 24:00
562
1st period stop time
00:00 … 24:00
563
2nd period start time
00:00 … 24:00
564
2nd period stop time
00:00 … 24:00
565
3rd period start time
00:00 … 24:00
566
3rd period stop time
00:00 … 24:00
576
Default values
No | Yes
The Ecomod Heat Pump Control provides a DHW pre-heating function via the Ecomod
heat pumps and a plate exchanger.
In order to optimiser product performance, DHW pre-heating by the Ecomod is
programmed for specific time ranges.