10
Mexico Super RS 3/60P - 3/100P -
Installation
INSTALLATION
The boiler is supplied fully assembled in Pack
A, together with either one or two of four
packs:
B, B1, C
or
D.
Packs
B, B1
or
C
contain the flue terminal appropriate to the
wall thickness.
Pack D
contains the flue
terminal extensions.
Unpack and check the contents.
INST
ALLA
TION
PACK 'A' CONTENTS
z
Complete boiler assembly.
z
The Hardware Pack (listed separately below).
z
These Installation and Servicing Instructions.
z
User's Instructions.
HARDWARE PACK
z
1" BSP plugs - 6 off
z
1" x
1/2
" BSP reducing
bush - 1 off
z
Distributor tube
z
Thermostat pocket -1 off
z
Thermostat clip - 1 off
z
Thermostat retaining pin - 1 off
z
Output setting label -1 off
z
Sachet of sealing mastic - 2 off
Pack D contents
z
Adhesive tape
4
UNPACKING
complete boiler assembly
Wall thickness
Flue
Dimension (duct length) X shown above
pack(s)
Boiler fitted flush with wall
Boiler fitted in line with 600 mm kitchen units
required
114 to 191 mm
(4
1/2
" to 7
1/2
")
up to 125 mm
(up to 5")
C
229 to 305 mm
(9" to 12")
163 to 242 mm
(6
1/2
" to 9
1/2
")
B
318 to 394 mm
(12
1/2
" to 15
1/2
")
253 to 332 mm
(10" to 13")
B1
406 to 584 mm
(16" to 23")
340 to 518 mm
(13
1/2
" to 20
1/2
")
B & D
Table 6: this table shows the number of flue packs required for the given wall thicknesses
z
Sachet of sealing mastic - 2 off
z
Flue terminal extension
FLUE PACKS
Packs B, B1 and C contents
z
Flue terminal assembly