3
Mexico Super RS 3/60P - 3/100P -
Installation
Boiler Size
RS 3/60P
RS 3/75P
RS 3/100P
Boiler Input
NOMINAL
kW (Btu/h)
21.4 (73 000)
28.2 (96 200)
35.7 (121 800)
Gas Consumption
l/s (ft.
3
/h)
0.225 (29.2)
0.297 (38.5)
0.376 (48.7)
Boiler Output to Water
NOMINAL
kW (Btu/h)
17.5 (59 600)
23.2 (79 000)
28.8 (98 100)
Burner Setting Pressure (hot)
NOMINAL
mbar (in w.g.)
35.2 (14.1)
35.1 (14.0)
35.2 (14.1)
Inlet Pressure
NOMINAL
mbar (in w.g.)
37 (14.8)
Flue Gas Flow Rate
g/s
10.3
13.5
17.1
Flue Gas Temperature
0
C
156
159
169
Seasonal Efficiency (SEDBUK)*
%
73.5
73.6
72.9
GENERAL
Table 1 - General Data
Table 2 - Performance Data
Notes.
1.
Gas consumption is calculated using a calorific value of
95.0 MJ/m
3
(2500 Btu/ft.
3.
)
2.
To obtain the fuel consumption in liquid form divide the
above figures by 270.
3.
The appliance is pre-set at the factory to give the nominal
output at an inlet pressure of 37 mbar (14.8 in.w.g.)
4.
A conversion kit is available to convert this applicance for
use on natural gas. This kit contains all parts and
instructions for setting up on natural gas. Once converted it
is not possible to convert back to propane gas.
Key to symbols
IE
= Ireland
GB
= United Kingdom (Countries of destination)
PMS
= Maximum operating pressure of water
C
11
= A room sealed appliance designed for connection via
ducts to a horizontal terminal, which admits fresh air to
the burner and discharges the products of combustion
to the outside without a fan in the combustion products
circuit.
II
2
H3P
= An appliance designed for use on 2nd Family gas,
Group H only and 3rd Family gas group P.
Boiler Size
RS 3/60P
RS 3/75P
RS 3/100P
Gas Supply Connection
in. BSP
Rc 1/2 (1/2)
Rc 1/2 (1/2)
Rc 3/4 (3/4)
Number of Boiler Sections
3
3
4
Flow and Return Connections
Rc 1 (1" BSP)
MAXIMUM Static Water Head
m (ft.)
30.5 (100)
(3 bar)
MINIMUM Static Water Head
m (ft.)
1.0 (3.3)
Electrical Supply
230 V ~50 Hz
External Fuse Rating (Power Consumption)
3 A
(5 W)
Water Content
litre (gal.)
7.4 (1.6)
7.4 (1.6)
9.8 (2.1)
Dry Weight excluding terminal
kg. (lb.)
90 (198)
90 (198)
113 (249)
Boiler Size
Height
mm (in.)
850 (33.5)
Width
mm (in.)
440 (17.4)
Depth
mm (in.)
533 (21.0)
Gas Type
I I
2H 3P
*
The value is used in the UK government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by BGplc 0087