13
Mexico Super RS 3/60P - 3/100P -
Installation
INSTALLATION
INST
ALLA
TION
8
FITTING THE FLUE ASSEMBLY
-
Duct lengths up to 400 mm (16") -
RS 3/60P ONLY
Flue terminal
shown in position
A.
Air duct join
B.
Flue duct join
6.Terminal grille
securing screws - 2 off.
7.Terminal flue securing screws - 4 off.
Legend
1.Boiler air duct.
2.Boiler flue duct.
3.Terminal air duct.
4.Terminal flue duct.
5.Terminal grille.
5.Terminal grille assembly.
6.Terminal grille.
7.Securing screws - 2 off.
8.Splitter plate.
Legend
1.Boiler air duct.
2.Boiler flue duct.
3.Terminal air duct.
4.Terminal flue duct.
9 FITTING THE FLUE ASSEMBLY
-
Duct lengths up to 400 mm (16") -
RS 3/75P & RS 3/100P
1.
Remove the 2 securing screws (6) and separate the terminal
grille from the terminal assembly.
2.
Remove the 4 securing screws (7) and separate the terminal
flue duct from the terminal air duct.
3.
From OUTSIDE of the building, pass the terminal air duct
through the wall opening and slide it into the boiler air duct,
locating it as shown.
4.
Push the terminal air duct fully in until the fixing brackets
contact the wall face.
5.
Ensure that the duct is level and make good between the
wall and duct, from OUTSIDE of the building.
6.
From OUTSIDE of the building, seal the air duct join (A) with
the mastic provided.
7.
From OUTSIDE of the building, pass the terminal flue duct
through the wall opening and slide it into the boiler flue duct.
Locate it as shown and fix it in position with the 4 screws
previously removed.
8.
From OUTSIDE of the building seal the flue duct join (B)
with the mastic provided.
9.
Fasten the terminal grille to the duct assembly.
1.
Remove the 2 screws and separate the terminal grille,
terminal air duct and terminal flue duct.
2.
From OUTSIDE of the building, pass the terminal air duct
through the wall opening and slide it into the extension air
duct, locating it as shown.
3.
Push the duct fully in until the fixing brackets contact the
wall face.
4.
Ensure that the duct is level and make good between the
wall and the duct from OUTSIDE of the building.
5.
From OUTSIDE the building, seal the duct join (A) with the
mastic provided.
6.
From OUTSIDE the building, pass the terminal flue duct
through the wall opening and slide it into the boiler flue duct
pushing the flue duct fully in, up to the locating stops.
Locate it as shown.
7.
From OUTSIDE of the
building, seal the duct join
(B) with the mastic provided.
8.
Fasten the terminal grille to
the duct assembly.
A.
Air duct join
B.
Flue duct join
Flue terminal
shown in position