6
Buccaneer GTE -
Installation & Servicing
GENERAL
1
BOILER DIMENSIONS
B
C
D
E
F
GT 4
692
812
125
427
50
GT 5
819
939
125
554
50
GT 6
946
1066
153
681
99
buc5489
355
C
60
F
60
300
35
835
289
570
E
163
B
392
562
137
1
4
2
3
120
285
570
158
1 Heating supply R 1
1
/
4
2 Heating return R 1
1
/
4
3 Drain cock
(connection for pipe ø int. 14 mm)
4
4 x M8 on
110
Insulation Cutout
2
BOILER CLEARANCES
The minimum dimensions indicated on
the following drawing must be respected
to ensure good access around the
boiler.
Note
.
To allow the inlet of the combustion air,
the boiler room must be adequately
ventilated, the section and the location of
which must comply with local
recommendations.
0.5
m
A
1m
0.5
m
0.5
m
570
835
Boiler A
(mm)
GTE 4
692
GTE 5
819
GTE 6
946
buc5490
Summary of Contents for Buccaneer GTE 5
Page 1: ......
Page 38: ...38 Buccaneer GTE Installation Servicing NOTES...
Page 39: ...39 Buccaneer GTE Installation Servicing NOTES...