44
BOXER
combination boiler -
Installation and Servicing
SERVICING
70 DHW FLOW SWITCH REPLACEMENT
1.
Refer to Frame 49.
2.
Remove the casing. Refer to Frame 41.
3.
Remove the expansion vessel and shield/air
guide. Refer to Frame 43.
4.
Close the DHW inlet valve and open the DHW tap
placed in the lowest position of the installation.
5.
Disconnect the electrical lead from the flow
switch.
6.
Unscrew the upper and lower nut fixing the flow
switch and remove it.
7.
Fit the new flow switch and re-assemble in
5
6
6
71 IGNITION TRANSFORMER REPLACEMENT
1.
Refer to Frame 49.
2.
Remove the casing. Refer to Frame 41.
3.
Remove the expansion vessel and shield. Refer to Frame
43.
4.
Disconnect the electrical leads from the ignition
transformer.
5.
Remove the screws securing the ignition transformer heat
shield and remove the assembly
6.
Unscrew the screw fixing the ignition transformer to the
protection shield and remove it.
7.
Refit the new ignition transformer and re-assemble in
reverse order.
6
7
reverse order using the new seals provided.
8.
Open the DHW inlet valve and close the DHW tap.
BOXER C 24
BOXER C 28
SER