Subject to technical changes | Valid as of January 2022
35
CALEO COLD/NEUTRAL
2.5.3. Installation of the unit above 2000 m above sea level
The unit is intended for use up to 2000 m above sea level.
When used above 1500 m above sea level, pressure relief must be provided for insulating glass to prevent damage to the glass. All
insulating glass display cases are delivered WITHOUT pressure relief as standard. Contact your service partner or the manufacturer
for more information.
The manufacturer is not liable for any damage caused to the unit or components (e.g. glass breakage, etc.) in the event
of incorrect installation or additional modifications required (e.g. pressure relief) for specific environmental parameters
of the unit.
NOTE
Connection of the units in the base:
All adjacent units must be connected in the base. For this purpose, mounting aids (fastening nuts) are pre-mounted in the base on
each side of the unit. Connect two units that are beside each other with the help of a screw (M8) in the designated fastening nuts.
Check the hold of each connection.