MODULE PROGRAMMING PROCEDURE - WITH TWO OEM KEYS
12
Module Programming
Procedure completed.
1
Insert key 1 into ignition.
5
Insert key 2 into ignition.
3
If LED turns solid GREEN for 2
seconds. Module Programming
Procedure completed.
If LED turns solid RED, proceed
with following step within 5
seconds, after LED turns OFF.
9
Press and release programming
button.
10
Remote start vehicle.
OR
Jump the igntion to 12volts.
12V
IGNITION
10 AMPS
2
Turn key 1 to ON position.
ON
6
Turn key 2 to ON position.
ON
!
If the LED begins to fl ash RED, verify the RX and TX
connections between the module and the vehicle.
!
If the LED begins to fl ash RED, you are using a cloned
key or used the same key twice.
7
Wait, LED will turn solid RED
then will turn OFF.
11
Wait, LED will turn solid RED
then will turn solid GREEN.
NOTE
I
To complete this procedure,
both OEM keys are required.
II
Keep both OEM remotes
at least 10 feet away from
the vehicule.
Use both valet keys for the
module programming procedure.
OR
4
Remove key.
8
Remove key.
ADS-AL(TB)-FM2