20
UL and ULC Installation Requirements
i
Only UL / ULC listed compatible products are intended to be connected to a UL / ULC listed control
system.
20.1
UL/ULC Installation Cabinet Options
UL/ULC Central Station Fire Monitoring, Central Station Alarm Installations
Cabinet Model
Manufacturer
UL/ULC Installation Listings
EN-DIN-24-ATTACK
ICT
UL1610, UL1635, ULC-S304, ULC-S559
Electronic Access Control System Installations
UL
ULC
All cabinet installations of this type must be located inside the Protected Area. Not to be mounted on
the exterior of a vault, safe or stockroom
Cabinet Model
Manufacturer
UL/ULC Installation Listings
EN-DIN-12
ICT
UL294, CAN/ULC-S319
EN-DIN-31
ICT
UL294, CAN/ULC-S319
EN-DIN-24
ICT
UL294, CAN/ULC-S319
EN-DIN-24-ATTACK
ICT
UL294, CAN/ULC-S319
All cabinet internal covers and lid/doors must be connected to the cabinets main ground point for
electrical safety and static discharge protection.
20.2
Central Station Signal Receiver Compatibility List
IP Receiver via Ethernet Port : Integrated Control Technology ArmorIP Internet Monitoring Receiver. Serial
interface to be used with SIMS II version 1.3x central station automation system software and compatible
receiving equipment as indicted in the SIMS II Appendix E UL Supplement.
CID Receiver via Onboard Modem: Any UL and ULC listed receiver that uses the Contact ID protocol.
20.3
ULC Compliance Requirements
CAN/ULC-S304-06
Auto Arming
Control units that support auto arming shall provide an audible signal throughout the protected area not less
than 10 min prior to the auto arming taking place. The control unit shall allow authorized users to cancel the
auto arming sequence and transmit such cancelation to the signal receiving center with the identification of
the authorized user that canceled the action.