background image

 

Ver. 1.04.19 
© 2012 -2019 by ICS

 

 
 

23 

 

Operating manual according to

 art. 14of 

the Ordinance on Hazardous Substances

 

Operating area: 
Working place:

 

Status: May 2012 

(based on SDB 4/ 2005)

Identification of hazardous substance 

Dry ice 

Other designation: Carbon dioxide – in frozen state 
CAS no.

: 124-38-9 

EU index no.: 

204-696-9 

 

Aggregate state

: solid 

Colour

: white  

 

Odour

: inodorous 

Flash point

Boiling point

:-78.5°C 

Melting point

: -56.6 °C 

Dangers for people and environment

 

Risk of frostbite development (-78°C) at skin contact 
Risk of suffocation because of the sublimated vapours (from 1 litre of dry ice result 
460 litres of gas) 
Loss of mobility and consciousness 
The  gas  released  through  evaporation  is  heavier  than  air  and  can  accumulate  in 
lower spaces. 

First aid measure and rules of conduct 

Protective measures

:

 

-     Avoid contact of the product with skin and eyes; 

-

 

During usage, ensure proper ventilation in the room; 

-

 

During  the  shredding  operation,  avoid  dispersion  of 
the chips; 

-

 

Do not transport with elevator if the elevator is being 
used by people; 

-

 

Avoid  protrusion  of  the  gas  released  by  evaporation 
in the sewerage or in lower areas. 

Eye protection

:

 

 

Wear goggles with tight-closing system.  

 

 

 

 

Hand protection

 

Wear protective gloves made of leather or  

 

 

 

low temperature resistant gloves 

Suitable extinguishing agents 

According to the conditions; carbon dioxide does not burn  

 

 

 

Storage

:

 

 

 

-  not to be stored in basements and unventilated spaces; 

-

 

not  to  be  stored  in  gas-tight  containers  (risk  of 
bursting because of high pressure). 

First aid measures 

Injured  persons  have  to  be  transported  out  of  the  danger  area,  using  protection  means,  proper 
ventilation  has  to  be  ensured,  in  case  of  high  concentration  levels,  a  self-contained  breathing 
apparatus has to be used. 

Administering first aid 

General information

 

After inhalation

 

Ensure  proper  ventilation,  in  case  a  person  becomes 

unconscious,  the  victim  should  be  positioned  in  a  stable  side  position,  in  case  of 
respiratory arrest administer artificial respiration, seek medical assistance. 

In case of skin contact

 

In case of frostbites, rinse for 15 minutes with lukewarm water. 

In  case  of  eye  contact

 

Rinse  eyes  for  at  least  15  minutes,  afterwards  see  an 

ophthalmologist.  

After swallowing

 

Drink plenty of water, seek medical assistance. 

Appropriate disposal 

The dry ice residues can be stored outdoors and left to evaporate, but only under strict supervision. 

For additional information, contact the Labour Protection Department. 

 

 

Summary of Contents for IC 022

Page 1: ...S Operating manual IC 022 Ver 1 04 19 ICS ice cleaning systems s r o Robotn cka 2192 Pova ska Bystrica 01701 SLOVAKIA Tel 421 42 4261 135 Fax 421 42 4330 248 E Mail support ics dryice com Internet www...

Page 2: ...and components of the front side 11 Connections and components of the back side 12 Operation of the blasting gun IG 022 13 Start up 14 Shut down 14 Filling the hopper of the IC 022 15 Transport 16 Req...

Page 3: ...eight Poids Druck max Pressure max Pression max Baujahr Year of manufacture Ann e de fabrication Your contact to ICS ICS ice cleaning systems s r o Robotn cka 2192 Pova ska Bystrica 01701 SLOVAKIA Tel...

Page 4: ...unit takes no responsibility of damages to the unit or caused by the unit in case of Disregarding these operating instructions Improper use or handling of IC 022 Repair and maintenance by unauthorized...

Page 5: ...fety glasses 2 Ear protection 3 Long sleeved working suit 4 Protective gloves 5 Dust mask 6 Safety shoes Caution In poorly ventilated areas the elevated concentration of CO2 can lead to breathing diff...

Page 6: ...2012 2019 by ICS 6 Emergency stop The emergency stop button interrupts all functions of the unit immediately Caution Despite the use of the emergency stop button the unit is still under pressure Emer...

Page 7: ...toring the dry ice pellets longer than 15 minutes in the dry ice hopper to avoid freezing of the IC022 Hopper and dosing system may freeze if remaining ice stays in the hopper Therefore the hopper has...

Page 8: ...only in flawless condition and repair any damages immediately see page 18 High electrostatic charges may occur Always make sure that the object to be cleaned is grounded and remains so for the durati...

Page 9: ...eration pressure min 4 bar max 10 bar Air consumption 0 3 m min 1 1m depending on the chosen combination of nozzle and operating pressure Requirements for the compressed air ISO 8573 1 2010 1 4 1 Comp...

Page 10: ...fficients The CO2 granulate sublimes in the moment of impact from solid to gaseous state Only the initial dirt remains behind The dry ice pellets in the hopper 3mm will be mixed using a compressed air...

Page 11: ...nections and components of the IC 022 Connections and components of the front side The blasting hose package including the control line is connected firmly with the IC 020 Blast gun Hopper lid Pressur...

Page 12: ...essed air hose with the quick coupling NW 7 2 by pressing the hose coupling onto the nipple until it clicks To remove press the coupling of the non pressurized compressed air hose towards the machine...

Page 13: ...be interrupted so that you can carry out the final dry of the blasted surface only with compressed air With the pressure control valve you set desired blasting pressure directly on the gun The IC 022...

Page 14: ...sed air source slowly 5 Aim the blasting gun towards the floor and press it for about 10 seconds to release the residual moisture from the dosing system 6 Now fill the hopper with dry ice pellets and...

Page 15: ...er 1 04 19 2012 2019 by ICS 15 Filling the hopper of the IC 022 Open the hopper lid and fill the hopper with 3mm dry ice pellets maximum 4kg and close the hopper lid Hopper lid Insulated dry ice hoppe...

Page 16: ...ts for the compressed air For an efficient blasting result the compressed air to be used is of outermost importance The compressed air should be dry clean oil free and free of foreign bodies We recomm...

Page 17: ...ow The IC 022 must be maintained regularly but not later than 12 months See the annual inspection plate on the unit Terms of warranty You warranty will be lost if the IC 022 is used improperly not ori...

Page 18: ...er filter cartridge and automatic drain or renew 7 Check compressed air cylinder for operation leaks and tightness 8 Check complete ice dosing system for wear operation and leak tightness 9 Check hopp...

Page 19: ...y No air on the gun Unit is running but there is no air on the gun Check the pressure control valve and open it No ice is coming out After triggering the gun only air is coming out but no ice Fill the...

Page 20: ...Ver 1 04 19 2012 2019 by ICS 20 Zeichnung IC 022...

Page 21: ...Ver 1 04 19 2012 2019 by ICS 21 Pneumatic plan IC 022...

Page 22: ...0 RV2 Drosselr ckschlagventil Bestandteil Steuerventil 51074 RV3 Drosselr ckschlagventil Bestandteil Steuerventil 51074 S1 Not Aus Taster 51009 S1 Not Aus Ventil 51000 S2 Microschalter Strahlpistole 5...

Page 23: ...e protection Wear goggles with tight closing system Hand protection Wear protective gloves made of leather or low temperature resistant gloves Suitable extinguishing agents According to the conditions...

Page 24: ...Ver 1 04 19 2012 2019 by ICS 24 EG...

Page 25: ...Ver 1 04 19 2012 2019 by ICS 25 ISO Certificate...

Reviews: