Ver. 1.04.19
© 2012 -2019 by ICS
14
Start-up
For the start-up of the IC 022 proceed as follows:
1.
Check
before each start-up
if the pressure control valve is closed.
2.
Connect the compressed air hose first with the quick coupling NW 7.2 on the rear
of the blasting unit and then with the compressed air source.
3.
Check the hose package and the gun for damages.
4.
Open the compressed air source slowly!
5.
Aim the blasting gun towards the floor and press it for about 10 seconds to
release the residual moisture from the dosing system.
6.
Now fill the hopper with dry-ice pellets and close the lid to prevent foreign
bodies entering the hopper.
7.
Now the IC 022 is ready for use.
Shut-down
After finishing the blasting work proceed as follows:
1.
Blast the dry-ice hopper until empty.
2.
Close the compressed air source.
3.
Actuate the gun to release the residual compressed air.
4.
Separate the compressed air hose from the unit.
5.