INSTALLATION / STOCKING INSTRUCTIONS 

 

SETTING UP THE CABINET 

 

 

Before using check to ensure that there is no damage to the cabinet. 

 

Remove all packaging, including any protective film. 

 

Select a location without direct exposure to sunlight. 

 

Select a location away from all heat and moisture generating equipment or sources. 

 

The cabinet must be installed on a flat and level surface to ensure correct operation. 

 

Installation must not be in a humid and / or dusty area. 

 

Ensure there is ample clearance behind the cabinet to allow correct airflow to the cabinet. 
A minimum of 10cm clearance must be between the cabinet and the sides / rear wall and a 
minimum of 2cm on the top of the cabinet to allow adequate air circulation.

 

Insufficient 

ventilation will cause the fridge to run outside the required operating temperature range and 
can cause permanent and expensive damage to both the compressor and vaccines. 

 

Connect the power cord into a grounded, 3 pin, 10AMP power point that has appropriate power surge 
protection. 

 

Ensure that your cabinet is connected to its own dedicated power point.  

Do not use an extension cord, double adaptor or power board. 

INSTALLING THE HANDLE 

 

 

Cut the cable tie holding the handle in place. 

 

Fit the handle to the left hand side of the door using the two screws already in position. 
 

INSTALLING THE BOTTOM SHELF 

 

 

 

Cut cable ties holding the ‘L’ shaped bottom shelf. 

 

Remove the ‘L’ shaped bottom shelf and place  
it on the floor of the refrigerator with the four ‘U’  
shaped legs on the floor of the cabinet. 

 

The vertical grill of this shelf must be at the  
back of the cabinet. 

 
 

STOCKING THE CABINET 

 

 

When stocking the top shelf, ensure that there is adequate (at least 10cm) ventilation beneath the fan 
cover, which is located above the top shelf. 

 

 

When stocking the shelves ensure that stock is 

not

 overhanging the sides of the shelves to ensure 

correct air circulation. Stock 

must not touch

 the front glass / internal side panels. 

 

 

When using containers such as boxes or trays on the shelves ensure there is adequate ventilation in 
the bottom of the containers and around the containers so that airflow is not restricted. If in any doubt 
whatsoever contact the Vaccine Supplier.

 

 

 

 

 

 

 

obstructing this space will prevent air 

circulation within the cabinet, and will result in 
temperatures outside of the required range.

 

Summary of Contents for G135L

Page 1: ...anual 31 Healey Road Dandenong South Victoria 3175 Australia P O Box 4140 Dandenong South BC Victoria 3164 Australia E mail info icspacific com au Web www icspacific com au Phone 61 03 9706 5115 Facsi...

Page 2: ...cabinet TABLE OF CONTENTS INTRODUCTION 2 SAFETY INSTRUCTIONS 3 SAFETY INSTRUCTIONS 3 INSTALLATION STOCKING INSTRUCTIONS 4 SETTING UP THE CABINET 4 INSTALLING THE HANDLE 4 INSTALLING THE BOTTOM SHELF...

Page 3: ...e cabinet off at the power point first and remove the 3 pin plug carefully from the power point Always disconnect the 3 pin plug of the cabinet from the power point before cleaning to avoid danger of...

Page 4: ...wn dedicated power point Do not use an extension cord double adaptor or power board INSTALLING THE HANDLE Cut the cable tie holding the handle in place Fit the handle to the left hand side of the door...

Page 5: ...wall Before cleaning the cabinet remove all products from within the cabinet When cleaning the cabinet interior exterior it is recommended that you use a solvent of warm water and mild detergent or a...

Page 6: ...LO Button and hold it in for 6 to 7 seconds The reset will be signalled by one long beep 4 Every time the high and low temperatures are checked it is important to clear and reset the displayed values...

Page 7: ...icator shows the fridge is in defrost The fridge will defrost every 6 hours This indicator will flash after defrost as part of its normal operation The UP Light Button 14 0 The UP Light button switche...

Page 8: ...p within the evaporator Ensure that the drain tube has not dislodged from the drip tray at the rear of the cabinet If there is condensation on the cabinet The ambient room temperature must not be abov...

Reviews: