67
C.7 States of a RAIDYNE® Disk Array
An Array Drive under the RAIDYNE® operating system can assume seven different opera-
tional modes:
Idle, Ready, Fail, Build, Rebuild, Expand and Error.
C.7.1 "Idle" State
This state is characterized by the fact that the redundant information of the disk array has
never been entirely created. The disk array is in this state after its first configuration and
until you quit ICPCON. If an error should occur while the array is in the
build
state, the array
returns to the
idle
state (exception: if during
build
mode the dedicated drive of RAID 4 fails,
the mode changes to
fail
).
C.7.2 "Build" State
After the disk array has been configured for the first time, it assumes the
build
state as soon
as you quit ICPCON. While the array is in the
build
state, redundancy information is calcu-
lated and stored to the hard disks of the array.
C.7.3 "Ready" State
The disk array is fully operational when in the
ready
state. All redundant information is pre-
sent, that is, a hard disk can fail without impairing the functionality of the disk array. This is
the normal state of a disk array. The state
ready/expand
indicates, that the RAID level and/or
capacity are currently migrated/expanded.
C.7.4 "Fail" State
The disk array changes to the
fail
state whenever a Logical Drive fails. Redundancy informa-
tion is still present, thus allowing the remaining hard disks to continue working. This state
should be eliminated as soon as possible by replacing the defective hard disk. If a so-called
Hot Fix drive has previously been assigned to a disk array with ICPCON, the controller will
automatically replace the defective drive and start the reconstruction of the data and the
redundant information. Therefore, under these circumstances the
fail
state is only tempo-
rary and will be eliminated by the controller itself.
C.7.5 "Rebuild" State
The disk array will assume this state after the automatic activation of a Hot Fix drive or after
a manual replacement carried out with ICPCON. The data and the redundant information
are reconstructed and stored to the new drive.
C.7.6 "Expand" State
If the capacity or RAID level of an existing disk array is changed, the disk array changes its
state into
expand
. As soon as the expansion or migration is completed, the state changes
back to
ready.
C.7.7 "Error" State
If a second hard disk should fail while the disk array is in the
fail
or
rebuild
state, it is not
possible to continue the working session without restrictions. The disk array is still avail-
able for I/Os, but data loss and error messages on the host level are possible.
The following state diagram of the disk array summarizes the states described above and
the transitions from one state to another.
Summary of Contents for GDT RS Series
Page 2: ...2...
Page 14: ...14 L 1 Technical Data of the ICP Controller 184 L 2 Boot Error Messages 184 L 3 Index 185...
Page 15: ...15 Chapter A General General General General Information Information Information Information...
Page 40: ...40 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Page 41: ...41 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Page 47: ...47 Several internal Wide Ultra2 and Ultra 160 SCSI Hard Disks...
Page 52: ...52...
Page 53: ...53 Chapter C Quick Setup Quick Setup Quick Setup Quick Setup...
Page 68: ...68 Replacement either manually or through hot fix method...
Page 70: ...70...
Page 71: ...71 Chapter D Using MS DOS Using MS DOS Using MS DOS Using MS DOS...
Page 81: ...81 Chapter E Using NetWare Using NetWare Using NetWare Using NetWare...
Page 88: ...88...
Page 96: ...96...
Page 97: ...97 Chapter G Using LINUX Using LINUX Using LINUX Using LINUX...
Page 102: ...102...
Page 103: ...103 Chapter H Using SCO UNIX Using SCO UNIX Using SCO UNIX Using SCO UNIX...
Page 110: ...110...
Page 111: ...111 Chapter I Using UnixWare Using UnixWare Using UnixWare Using UnixWare...
Page 147: ...147 Chapter K ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator...
Page 182: ...182...
Page 183: ...183 Chapter L Appendix Appendix Appendix Appendix...