![ICP DLF4AH09J1A Service Manual Download Page 23](http://html1.mh-extra.com/html/icp/dlf4ah09j1a/dlf4ah09j1a_service-manual_3576760023.webp)
SERVICE MANUAL
R
−
410A Ductless Split System: DLF4(A/H), DLC4(A/H)
421 08 9204 00
23
SYSTEM OPERATING ENVELOPES
Supply Voltage
115-1-60 AC
208/230-1-60 AC
Model Size
9k
12k
12k
18k
24k
30k
36k
Indoor Operating Range (A/C and HP)
°
F (
°
C)
61 - 86 (16 - 30)
Cooling Ambient Operating Range (A/C)
°
F (
°
C)
55 - 115
(13 - 46)
55 - 115
(13 - 46)
5 - 109
(-15 - 43)
5 - 109
(-15 - 43)
5 - 109
(-15 - 43)
N/A
64 - 109
(18 - 43)
Cooling Ambient Operating Range (HP)
°
F (
°
C)
55 - 115
(13 - 46)
55 - 115
(13 - 46)
5 - 109
(-15 - 43)
5 - 109
(-15 - 43)
5 - 109
(-15 - 43)
5 - 109
(-15 - 43)
64 - 109
(18 - 43)
Heating Ambient Operating Range (HP)
°
F (
°
C)
5 - 75
(-15 - 24)
5 - 75
(-15 - 24)
5 - 75
(-15 - 24)
19.4 - 75
(-7 - 24)
19.4 - 75
(-7 - 24)
19.4 - 75
(-7 - 24)
19.4 - 75
(-7 - 24)
Figure
3
4
5
6
Figure 3
-
9k / 12k 115V System Operating Envelopes
Figure 4
-
12k 230V System Operating Envelopes