SERVICE MANUAL
R
−
410A Ductless Split System: DLF4(A/H), DLC4(A/H)
421 08 9204 00
17
STANDARD FEATURES AND ACCESSORIES
Ease of Operation
Mounting Brackets
S
Low Voltage Connections
S
Comfort Features
Microprocessor Controls
S
Wireless Remote Control
S
Rapid Cooling/Heating
S
Automatic Air Sweep
S
Cold Blow Prevention
S
Continuous Fan
S
Auto Restart Feature
S
Memory Function
S
Auto Changeover
S
Energy Saving Features
Inverter Driven Compressor
S
Sleep Mode
S
24 Hour Stop/Start Timer*
S
Safety and Reliability
Indoor Unit Freeze Protection
S
3 Minute Compressor Time Delay
S
High Compressor Discharge Temperature
S
Low Voltage Protection
S
Compressor Overload Protection
S
Compressor Over Current Protection
S
IPM Module Protection
S
Ease of Service and Maintenance
Cleanable Filters
S
Diagnostic LED’s ON Outdoor Board
S
Error Messages Displayed Front Panel
S
Application Flexibility
Condensate Pump
A
Low Ambient Heating and Cooling on most models
A
Standard Warranty
7 Year Compressor Limited Warranty
S
5 Year Parts Limited Warranty
S
Extended Warranty
6
−
10 Year Compressor Only
O
2
−
6 Year Parts Only
O
2
−
6 Year Parts Only; 1
−
6 Year Labor
O
2
−
6 Year Parts Only; 6
−
10 Year Compressor Only;
1
−
6 Year Labor
O
Legend
S = Standard
A = Accessory
O = Optional
* Sizes 09, 18, & 24K have a clock.
16’ Transparent
Suction Discharge Tubing
Condensate Pump
Assembly
Low Voltage
Power Cord
Transparent
Detection
Unit Vent Tubing
Detection Unit
5/8” Rubber Elbow
Detection Unit
Mounting Bracket
Wire Ties (6)
Mounting Bracket
Power Cable
Adhesive
A12227
Figure 1
-
Accessory Condensate Pump Kit
Table 1
−
Accessory
Condensate Pump Kit Contents
Item
Qty.
16 ft Transparent Suction/Discharge Tubing
1
Condensate Pump Assembly
1
Low voltage Power Cord
1
Transparent Detection Unit Vent Tubing
1
Power Cable
1
Wire Ties
6
Wall Mount Bracket
1
Adhesive
1
Detection Unit Mounting Bracket
1
⅝
−
in Rubber Elbow
1
Detection Unit
1
!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position.
Ensure power is disconnected to the fan coil unit. On some
systems both the fan coil and the outdoor unit may be on
the same disconnect. There may be more than 1 disconnect
switch. Lock out and tag switch with a suitable warning
label.