Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice. 

Dimensions 

See diagrams opposite 

Weight 

0.1kg 

Supply Voltage 

/- 10%  

Frequency 

50Hz 

Maximum Load 

Channel 1 (switching):

 

10A of lighting and/or ventilation 

including incandescent, fluorescent, 
compact fluorescent, low voltage (by 
switching the primary of transformer). 

Channel 2 (dimming): 

Maximum number of 1-10V 
ballasts is 10.

 

Terminal Capacity 

2.5mm

2

 

Technical data 

Related products 

EBDSPIR-AT-PRM 

RF Ceiling PIR presence detector – switched 

EBDSPIR-AT-DD   

RF Ceiling PIR presence detector – DALI/DSI dimming 

AT-BB-IN   

 

RF Input unit 

AT-SL-R 

 

 

RF relay controller 

AT-SL-R-SA  

 

RF relay controller (standalone) 

AT-SL-DDR  

 

RF DALI/DSI + relay controller 

AT-SL-DDR-SA 

 

RF DALI/DSI + relay controller (standalone) 

AT-SL-ADR  

 

RF 1-10V + relay controller 

AT-SL-ADR-SA 

 

RF 1-10V + relay controller (standalone) 

VITM4-ATMOD 

 

RF Switching module 

VITM6-ATMOD-AD 

RF VITM6 1-10V module 

VITM6-ATMOD-DD 

RF VITM6 DALI/DSI module 

UHS4  

 

 

Programming IR handset 

UNLCDHS   

 

Universal LCD IR handset 

C.P. Electronics Ltd

 

Brent Crescent 
London 
NW10 7XR 
United Kingdom 
Tel: 

+ 44 (0) 333 900 0671 

Fax: 

+ 44 (0) 333 900 0674 

www.cpelectronics.co.uk 
[email protected] 

Ref:  #WD382    Issue 2 

FM 45789 

EMS 534520 

Receiver Class 

Transmitter Duty Cycle  <10% on g3 band (default band) 

<0.1% on g2 band 
<1% on g1 band 

Range 

The maximum RF range between An-10 
devices is 100m in free air and up to 30m 
indoors. However the materials used within 
a building will vary and this will impact upon 
the RF range. In reality the nature of how 
the An-10’s hybrid-mesh works means that 
in most scenarios the individual range of an 
An-10 product will not be important. 

 

 

Temperature 

0ºC to 35ºC 

Humidity 

5 to 95% non-condensing  

Material (casing) 

Flame retardant ABS Type Class 2 

Order 
code 

Region 

Radio 
frequency 

Compliance  

blank 

European 
Union 

868MHz 

EN300 220-2 V2.1.2 
EN301 489-1 V1.8.1 
EN301 489-3 V1.2.1 
LVD-2006/95/EC 

-A2 

Australia & 
New Zealand 

915MHz 

AS/NZS 4268:2008 

Hereby, CP Electronics Ltd, declares that this EBDSPIR-AT-AD is in compliance with the essential 
requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity 
may be obtained for CP Electronics Ltd Brent Crescent, London, NW10 7XR, UK. 

Summary of Contents for EBDSPIR-AT-AD

Page 1: ...ts e g the AT BB IN Input Unit useful for push button scene selection and absence detection All functionality is fully programmable Features PIR Sensor Detects movement within the unit s detection range allowing load control in response to changes in occupancy IR Receiver Receives control and programming commands from an IR infrared handset Light Level Sensor Monitors the ambient light level allow...

Page 2: ... forced air heating or ventilation Do not fix the sensor to an unstable or vibrating surface Position the sensor so that the occupants of the room fall inside the detection zone shown in below Note that the detection zone illustrated is based on a recommended mounting height of 2 8m A lower height will decrease the overall size of the detection zone Installation Area of lower sensitivity Area of h...

Page 3: ...ed by a qualified electrician in accordance with the latest edition of the IEE Wiring Regulations and any applicable Building Regulations Mounting procedures WARNING Be careful bending springs when mounting unit Installation Mounting Methods The EBDSPIR AT AD is designed to be mounted using either Flush fixing or Surface fixing using the optional Surface Mounting Box part no DBB Both methods are i...

Page 4: ... switched output of the EBDSPIR AT AD can either be used to switch a separate channel of standard non dimming luminaires or to isolate the mains supply to dimming ballasts saving on the standby current of the ballasts Multiple luminaires may be connected in parallel to Channel 1 via the N and L Out terminals as long as the maximum total load is not exceeded Channel 2 dimmable output of the EBDSPIR...

Page 5: ...dressed see Step 1 Set channel addresses and channel load type on page 7 If the detection range is smaller than expected check the diagrams in page 2 Rotating the sensor slightly may improve the detection range HINT The Walk Test LED function can be used to check that the unit is detecting movement in the required area see page 8 for further details What if the load does not turn OFF Ensure that t...

Page 6: ... Handset UNLCDHS Infrared Handset with LCD For most basic programming operations the UHS4 handset is recommended and the following procedures are based on using this device Point the handset at the Sensor and send the required programming commands to the unit as shown in Steps 1 2 and 3 Valid commands will be indicated by a green LED flash See page 1 for details of other LED responses ...

Page 7: ... that also have a Local Code of 1 To program the settings for a specific channel on the Sensor you must specify the appropriate channel number i e 1 to 3 using the programming device If no channel number or channel 0 is specified all channels will be set to the same address The output channels also have Circuit numbers This allows different physical channels to be linked and controlled as a single...

Page 8: ...sh red when movement is detected By default when the detector turns on Local Scene 1 is selected When the detector turns off Local Scene 20 is selected See Scenes Used for Occupancy Detection in Step 3 for further details Switch Level On Off Occupancy detection can be made dependant on the ambient light level using the Lux On Level and Lux Off Level parameters Maintained Illuminance The detector m...

Page 9: ... has a Fade Rate which is the time taken for the existing output channel levels to fade to the levels defined in the selected Scene By default this is set to 3 seconds for all Scenes Each Scene also has a Maintained Illuminance Level setting By default this is set to 0 i e disabled for all Scenes Scenes Used for Occupancy Detection If movement is detected in Presence mode Local On Scene 1 is selec...

Page 10: ...d Similarly the corridor lights are controlled by two sensors such that if either sensor detects movement all of the corridor lights turn on Note that only one sensor is physically wired to the lighting circuit In this arrangement the devices in each room need to be programmed with a unique Local Code although the two devices in the corridor share the same code so that they can both control the co...

Page 11: ... lights via Channel 2 dimmed output Fully independent control of all four circuits can be provided with suitable scene programming Scene selection and manual control of all circuit levels can be achieved via an IR Handset In addition this example shows two AT BB IN input units used in conjunction with wall mounted button plates to provide manual selection of scenes Since the detectors are in Absen...

Page 12: ... channel Detection Mode Presence Presence or Absence Presence mode allows the output to turn on when movement is detected and off when movement ceases Absence mode allows the output to turn off when movement ceases but must be manually turned on first Output State Set by Scene 0 100 0 off The current output state of the channel for example as set by a Scene Select command Light Level maintained il...

Page 13: ...0 0 to 100 Maximum dimming output level Min Value 0 0 to 100 Minimum dimming output level Maintained Illuminance Level Set by Scene 0 disabled or 1 to 999 The maintained illuminance target level of the channel when under manual control for example as set by a Scene Select command Max Maintained Illuminance output level 100 0 to 100 Set the maximum maintained illuminance level for the channel Min M...

Page 14: ...ment Lux off level Switch level off 700 0 disabled or 1 to 999 Sets a maximum light level above which the PIR sensor is disabled preventing lights from being turned on by movement Light Level maintained illuminance 550 0 disabled or 1 to 999 Sets a target light level to be maintained by the lighting system Power Up State On On or Off When power is applied to the unit the PIR sensor goes through a ...

Page 15: ... If a Local and or Area Step Scene is specified this will be requested first when the Sensor switches off If a Step Scene is not specified or if it times out the Local and or Area Off Scene will be implemented NOTE Area Step and Off Scenes are ignored unless one or more Area Codes are set for the corresponding input channel and they match the Area Codes set in any output channel The values of the ...

Page 16: ...ming IR handset UNLCDHS Universal LCD IR handset C P Electronics Ltd Brent Crescent London NW10 7XR United Kingdom Tel 44 0 333 900 0671 Fax 44 0 333 900 0674 www cpelectronics co uk enquiry cpelectronics co uk Ref WD382 Issue 2 FM 45789 EMS 534520 Receiver Class 2 Transmitter Duty Cycle 10 on g3 band default band 0 1 on g2 band 1 on g1 band Range The maximum RF range between An 10 devices is 100m...

Reviews: