4.3 eIIIIIIIILDD…[CHK]<CR>
Description:
Send or receive an extended CAN data frame.
Syntax: eIIIIIIIILDD…[CHK]<CR>
e
Stands for the extended (2.0B) data frame.
IIIIIIII
29 bits Identifier (00000000~1FFFFFFF)
L
Data length (0~8)
DD…
Input data frame value according to the data length (00~FF)
Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the “Error Response” function in the CAN Converter Utility, in order to
receive Syntax and/or communication error information at the host PC.
Example:
Command: e1234567851122334455<CR>
Send a CAN message with an extended data frame. ID=12345678, DLC=5, data1=11,
data2=22, data3=33, data4=44 and data5=55.
I-7530, I-7530-FT, I-7530A, I-7565, tM-7530, tM-7530A, tM-7565 User Manual Version 1.5
Page
:
41
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved E-mail: [email protected]