4.9 P2BBDSPAE[CHK]<CR>
Description:
Change and apply the RS-232/RS-485/RS-422/USB parameters. These
parameters will not be saved. When the module is rebooted, the RS-232/RS-485/RS-422/USB
parameters will be recovered to the previous setting.
Syntax: P2BBDSPCE[CHK]<CR>
P2
Command character
BB
RS-232/RS-485/RS-422/USB Baud rate
D
Data bit
0 = 5 bits Data formation
1 = 6 bits Data formation
2 = 7 bits Data formation
3 = 8 bits Data formation
S
Stop bit (0=1 stop bit, 1=2 stop bits)
P
Parity (0=None, 1=Odd, 2=Even)
C
Checksum (0=No, 1=Yes)
E
Error Response (0=No, 1=Yes);
Table: RS-232/RS-485/RS-422/USB baud rate list
BB
Description
00
110 bps baud rate of RS-232
01
150 bps baud rate of RS-232
02
300 bps baud rate of RS-232
03
600 bps baud rate of RS-232
04
1200 bps baud rate of RS-232
05
2400 bps baud rate of RS-232
06
4800 bps baud rate of RS-232
07
9600 bps baud rate of RS-232
08
19200 bps baud rate of RS-232
09
38400 bps baud rate of RS-232
0A
57600 bps baud rate of RS-232
0B
115200 bps baud rate of RS-232
0C
230400 bps baud rate of RS-232, only for I-7565, tM-7530, tM-7530A,
I-7530, I-7530-FT, I-7530A, I-7565, tM-7530, tM-7530A, tM-7565 User Manual Version 1.5