Analog Input:
32 S.E./ 16 Diff. analog inputs for PEX-1202 and PCI-1202/1602/1802 series card.
16 S.E./8 Diff. analog inputs for PCI-1800 series card.
A/D converter = 12-bit, 330 k Samples/Sec. for PCI-1800/1802
(L/LU)
.
A/D converter = 12-bit, 110 k Samples/Sec. for PEX-1202
(L)
and PCI-1202
(L/LU)
.
A/D converter = 12-bit, 44 k Samples/Sec. for PEX-1202
(H)
and PCI-1202/1800/1802
(H/HU)
.
A/D converter = 16-bit, 200 k Samples/Sec. for PCI-1602
(F/FU)
.
A/D converter = 16-bit, 100 k Samples/Sec. for PCI-1602
(/U)
.
Programmable input signal configuration.
Provides “MagicScan” function.
FIFO Size: 1 k samples for PEX-1202
(L/H)
and PCI-1202/1800
(L/H/LU/HU)
.
8 k samples for PCI-1602
(/F/U/FU)
and PCI-1802
(L/H/LU/HU)
.
Three A/D trigger sources: software, Pacer and external trigger.
Three external trigger modes: pre-trigger, middle-trigger and post-trigger.
CHn
External trigger
End
Start
External
middle-trigger
t
N2
External trigger
t
Start
End
External post-trigger
CHn
External trigger
Start
End
CHn
External
pre-trigger
t
t
Start
End
Internal pacer trigger
CHn