2.7.4.
Introduction to Serial port for LP-9x2x
Figure 2.7.4-1 illustrates the ports contained on the LP-9821. The information is organized as
follows:
ttyO4─ Internal communication with the I-97KW modules in slots
ttyO5
─ RS-232/RS-485; Non-isolation; Console
ttyS0 ─ RS-485 (D2+, D2-; self-tuner ASIC inside)
ttyS1 ─ RS-232/RS-485
(RXD, TXD, CTS, RTS and GND for RS-232, Data+ and Data- for RS-485)
ttyS34 ─ RS-232
(RXD, TXD, CTS, RTS, DSR, DTR, CD, RI and GND)
Device name
Definition in LP-9x21 SDK
Default baudrate
ttyO4
COM1
115200
ttyO5 (RS-232/485/console)
None
115200
ttyS0 (RS-485)
COM2
9600
ttyS1 (RS-232/485)
COM3 (LP-9421/9821 only)
9600
ttyS34 (RS-232)
COM36 (LP-9421/9821 only)
9600
Figure 2.7.4-1.
Serial port mapping on the LP-9821