[Reject Remote Frame]
block:
<1>
“
Set
” button:
Checking the “Reject Remote Standard/Extended Frame” item to select
whether reject remote standard/extended CAN frame or not. After checking the
“Reject Remote Frame”, press the “Set” button to save the setting into module.
[Standard ID/Extended ID]
block:
<1>
“
CAN ID (HEX)
” block:
Press the “Add” button to add a range of standard/extended CAN ID into
“Standard/Extended ID Fiter” frame.
<2>
“
Get CAN Standard IDs/Get CAN Extended IDs
” button:
Get all the CAN Standard/Extended IDs setting from the module.
<3>
“
Set CAN Standard IDs/Set CAN Extended IDs
” button:
Set the CAN Standard/Extended IDs setting on “Standard/Extended ID Fiter”
frame into the module.
<4>
“
Re-Init CAN
” button:
All settings in the “CAN Filter Setting” will take effect after pressing “Re-Init CAN”
button.
<5>
“
Save File
” button:
Save the CAN Standard/Extended IDs setting on “Standard/Extended ID Fiter”
frame into an ini file.