I-7565M-FD USB to CAN/CAN FD converter User Manual (version 1.0.0)
Page: 24
Copyright © 2019 ICP DAS Co., Ltd. All Rights Reserved. E-mail: [email protected]
Figure 4-5 “Send Message” screen of the I-7565-FD Utility
[Send Message]
block:
<1>
“
Send Message Configuration
” frame
:
It is used to edit the CAN message parameters and users can use “Add” button
to add the CAN message to “CAN/CAN FD Message Send Area”.
Mode : CAN 11-bit (standard) ID or 29-bit (extended) ID.
ID :
CAN ID field of CAN/CAN FD frame.
RTR : Remote frame. Value 0 means this frame is a data frame. Value 1
means this frame is a remote frame
FDF : CAN FD frame. Value 0 means this frame is a CAN frame. Value 1
means this frame is a CAN FD frame
DL :
CAN message data length.
For CAN frames, this field can be set 0 ~ 8 (means 0 ~ 8 bytes data
length).
For CAN FD frames, this field can be set 0 ~ 8,
12/16/20/24/32/48/64 (means 0 ~ 8, 12/16/20/24/32/48/64 bytes
data length).
Data : Data field of CAN messages. Each data must split with ‘-’.
Timer(ms) :
Transmission cycle of the CAN message.
Unit: 1 millisecond.
<2>
“
Add
” button
:
It will add the CAN message from “Send Message Configuration” area to the
last row in “CAN/CAN FD Message Send Area”.
<3>
“
Modify
” button
:
It will modify the CAN message parameter from “Send Message Configuration”