14
2.4
Digital Input Wiring
Digital Input
Digital input channels
12 (3 switches for each motor)
Input type
Wet
Wet contact
ON voltage level
+10 to 24 V
DC
OFF voltage level
+4 V
DC
MAX
Photo-isolation
3750 V
DC
The diagram for Positive (RL) and Negative (LL) direction hardware limit switches and
home switch (ORG) wiring for axis X, Y, Z, and U is shown below.