Example 3:
Receive a CAN FD message from CAN1 of ECAN-200-FD at 10s.000us which
frame format is listed below
Extended CAN FD frame which CAN ID is 0x12345678
CAN Data length is 8 with data 0x11, 0x22, 0x33, 0x44, 0x55, 0x66, 0x77 0x88
CAN FD bit rate switch is enabled
Received Ethernet command will like below table.
Command
Data Content (Hexadecimal)
Note
Command Header Field
Header
0x55
Type
0x01
CAN1
Data Length
0x00 0x50
80
Command Data Field - Data1
CAN Message ID
0x12 0x34 0x56 0x78
CAN Message Format
0x00 0x0D
CAN Data Length Code
0x00 0x08
CAN Data
0x11 0x22 0x33 0x44 0x55 0x66 0x77 0x88
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
8 bytes
data valid
Timestamp (sec)
0x00 0x00 0x00 0x0A
10 s
Timestamp (micro-sec)
0x00 0x00 0x00 0x00
000 us