7. Typical Applications
This chapter provides some examples of typical scenarios for the ECAN-200-FD module,
including applications focused on the TCP Server and CAN Pair Connection applications.
7.1. TCP Server Application
The TCP Server function is used to implement communications between CAN devices and a
TCP Client device. When the ECAN-200-FD module is acting as a TCP Server, the TCP Client
device needs to use Ethernet commands base on the CAN/CAN FD format, listed in
, in
order to access the ECAN-200-FD module. Then ECAN-200-FD module will translate these
Ethernet commands into CAN/CAN FD format messages and send them to the CAN networks.
Similarly, when a CAN/CAN FD format message is received from the CAN network, the
ECAN-200-FD will translates the message into Ethernet commands and sent it to the connected
TCP client device.
ECAN-200-FD
Port1 Settings (CAN Network #1)
Local TCP/UDP Port
10001
Application Mode
TCP Server
Port2 Settings (CAN Network #2)
Local TCP/UDP Port
10002
Application Mode
TCP Server