ECAN-200-FD (Ethernet to 2-port CAN FD Converter) User Manual
Version 1.0.0
Page
:
42
Copyright © 2022 ICP DAS Co., Ltd. All Rights Reserved E-mail: [email protected]
Restore Factory Defaults
No. Function Name
Parameter Name Value Constraint
CGI
01
Reboot device
-
-
reboot.cgi
02
Reset all parameters To Factory
(No reboot device)
-
-
reset.cgi
Queries Setting Status
No. Function Name
Parameter
Name
Value
Constraint
CGI
01
Get module status.
-
-
status.cgi
02
Get the CAN port configuration information.
-
-
conf_port.cgi
03
Get the network configuration information.
-
-
conf_net.cgi
13
Set application mode
apm0 & apm1
0,1
0: TCP server mode;
1: UDP mode;
14
Set remote device IP of
UDP mode
rip0 & rip1
xxx.xxx.xxx.xxx
15
Set remote device port of
UDP mode
rp0 & rp1
1~65532
16
Set TCP connection timeout
of this port
tto0 & tto1
0~65535 seconds,
Default: 180;
Disable: 0;
17
Clear CAN port status
clrst0 & clrst1
1
1: clear