![background image](http://html1.mh-extra.com/html/icp-das-usa/can-8124/can-8124_user-manual_3568919125.webp)
CAN-8124/CAN-8224/CAN-8424 User Manual
CAN-8124/ CAN-8224/ CAN-8424 User Manual (Version 2.0, Aug/2007)
125/153
2. Apply the Master’s Explicit Request Messages to set the Identify
object. The service ID(0x05) is the reset service.
Master
(MAC
ID
=0x0A)
Slave
(MAC
ID
=0x09)
Then the slave sends the shutdown message to the CAN bus.
Master
(MAC
ID
=0x0A)
Slave
(MAC
ID
=0x09)
_ Group 2 Message
| _ Destination MAC ID=0x09
| | _ Message ID =4
| | | _ Frag=0. Transaction ID=0. Souce MAC ID= 0x0A
| | | | _ Service=Reset service
| | | | | _ Class ID=1
| | | | | | _ Instance ID=1
| | | | | | | _ Service Data= 0
ID=10 001001 100. Data= 0A 05 01 01 00
_ Group 2 Message
| _ Source MAC ID=0x09
| | _ Message ID =3
| | | _ Frag=0. Transaction ID=0. Destination MAC ID= 0x0A
| | | | _ Service= Reset Response
| | | | |
| | | | |
ID=10 001001 011. Data= 0A 85
_ Group 2 Message
| _ Source MAC ID=0x09
| | _ Message ID =3
| | | _ Frag=0. Transaction ID=0. Souce MAC ID=9
| | | | _ Service code= 0x4E, Device Shutdwon message
| | | | | __ Class ID=1
| | | | | | _ Instance ID=1
| | | | | _|__ __|__ _____ Shutdown Code
ID=10 001001 011. Data= 09 CE 01 00 01 00 04 00