CAN-8124/CAN-8224/CAN-8424 User Manual
CAN-8124/ CAN-8224/ CAN-8424 User Manual (Version 2.0, Aug/2007)
7/153
1.3 CAN-8124/CAN-8224/CAN-8424 DeviceNet Features
z
Complies with DeviceNet specification Volume I, Release 2.0&
Volume II, Release 2.0
z
Group 2 Only Slave; (non UCMM-capable)
z
Supports Predefined Master/slave Connection Set
z
Supports Explicit message connection
z
Supports Fragmented Explicit Message
z
I/O operating modes: Polling, Bit-Strobe, Change of State/Cyclic
z
Supports Fragmented IO (maximum 128 bytes output and/or 128
bytes input data)
z
Dynamic Assembly Objects Mapping;
z
Supports Device Heartbeat message
z
Supports Device Shutdown message
z
EDS file dynamically
z
Support all standard DeviceNet data rate: 125K, 250K and 500K bps
z
Data rate and Node Address (MAC ID) configured via rotary switch
z
NET, MOD and Power Led directors
1.4 Utility Feature
z
Support I-8k/I-87K modules
z
Show I-8k/I-87K modules configuration
z
Show Application and assembly objects configuration
z
Support IO connection path setting
z
Support EDS file creating