STEP 6

Now that you have preset your desired temperature and started the 
circulating pump, notice that the pump button will have changed from 
start to stop. You can use this same button to start and stop the pump at  
any time. Now, touch the start system button and the cooling cycle will 
begin. The water will be cooled to your pre-set temperature and the 
system will then cycle to maintain it at that temperature automatically. 

The system can only be started once within any 3 minute period to 
avoid overloading the compressor. So if you don’t hear it start when 
you touch the start system button, do not touch the again, the iCool 
will start automatically after the 3 minutes safety period elapses.

For the safety of users, you can not set temperatures below 5°C or 
above 45°C. (40°F-112°F) In an emergency you can stop all functions 
immediately by touching the “all stop” button however, if the cabinet is 
hot, only the fan may continue to run until the cabinet has cooled.

To change from cooling to heating or back you must restart.

The system on the left hand side can also heat and will automatically 
enter into either the cooling or the heating mode depending on your 

first  temperature  setting.  It  heats  and  cools  by  modern  heat  pump 

technology using as much less electricity. The right hand side is for 
cooling only, it does not heat.

Setting up to use the Heating Mode

For safety reasons you can only initiate the heating mode at the time 

the unit is first switched on. You can not change to heating while you 

are using it in the cooling mode or vice versa. You must switch off at the 
main switch and start again to change modes.

Your iCool selects either cooling or heating automatically

For example, if you set the temperature to a value that is BELOW the 
current water temperature in your pool it will automatically begin 
COOLING when you touch the START SYSTEM button. 

If you set the temperature to a value that is ABOVE the current water 
temperature in your pool it will automatically begin HEATING when you 
touch the START SYSTEM button. To use the heating function use the 
up down arrows to select the hot temperature you require up to 45ºC 
(or 108ºF) and then touch the START button. This takes you back to 
the main operating screen where you can now start the PUMP and the 
SYSTEM as usual. The status bar on the front of the unit will turn RED 
when you touch the START button to indicate that your iCool is now 
heating. It will continue to heat until it reaches your pre set temperature 
and then hold that temperature for as long as you wish.

You must use a pool cover when heating the water

We all understand heat rises, so you must use a cover on top of your 
pool when heating it or you will lose a large amount of the heat energy 
into the room and it will take much longer to heat the water.

The Loss of Water Flow Warning Screen

If water stops flowing for more than two minutes the iCool will sound 
a warning and shut down. This screen will appear.

The Water Flow Warning Screen also provides an option to over ride the 
flow protection system in the rare situation of a false alarm.

Once you use this function to disarm the flow safety monitor nothing 
will stop the system even if water is not flowing and this can seriously 
damage the pump as it will have no lubrication or cooling from the water. 

This over ride function is only to be used for short periods where it is 
essential to keep your system operating until the reason for the false 
alarm can be determined and corrected.

Water flow can also stop if the heat exchanger tank is frozen solid

If you set the temperature below about 7ºC or 45ºF it is occasionally 
possible in certain climatic conditions for the heat exchanger tank to 
freeze solid which will block the flow of water. 

In order to cool the pool water to these extremely low temperatures the 
system must cool to at least 5 to 7ºC below the set temperature and 
this takes it very close to the temperature that water freezes solid. 

Following international safety standards your iCool will not accept water 
temperature settings below 5ºC or 40ºF as this would put athletes 
using the system unattended at risk of hypothermia. However, the iCool 
is easily powerful enough to freeze the water and if this happens the 
safety screen above will appear and the system will stop.

WARNING

Never use this option unless you are absolutely certain that the 
system has stopped because of a false water flow alarm

Warning Screen

Summary of Contents for TWIN

Page 1: ...Owners Manual iCool TWIN ...

Page 2: ...olled heating Now you can provide advanced contrast therapy sessions at a much lower cost The Twin can provide any temperature used in recovery therapy into 2 pools at the same time One can be hot and one cold or both cold and all temperatures are accurately and automatically maintained The TWIN is the perfect solution for a world class recovery centre at an affordable price in fact the lowest pri...

Page 3: ...ugh your iCool is produced by a high quality long life circulating pump that includes an effective filter system to keep the pool water clean The pump with your iCool can not begin to operate correctly unless it is fed with a head of water from a pool therefore the level of water in the pool must be higher than the pump and any air tapped in the feeding hoses must be removed There must be no air t...

Page 4: ...in 4 3 Connect 5 to the bottom of the pool 2 To operate 2 pools simply repeat the illustration for the second pool STEP 1 2 QUICK START GUIDE The following is a quick start guide to get your iCool up and running quickly however you should read the entire manual to get the most out of your iCool WARNING The water level in the pool must be above the water inlet of the pump or the pump can not start ...

Page 5: ...anner It also provides a substantial amount of additional information to assist you When you turn on the power for the first time the system will load the latest software from its memory and run a diagnostic self test routine This will take about 20 seconds During this time you will see this screen shown at right and then a BLACK screen The System Status Bars will flash white The STATUS BARS on ea...

Page 6: ...r iCool is ready to use The Status bars glow BLUE when only the pump is running GREEN when the cooling system is running and RED when the heating system is running If the bars glow RED when you try to start cooling please refer to page 7 for an explanation Your twin is actually 2 separate iCool machines so they can be operated completely independently from each other If you only want to use one sy...

Page 7: ...mperature you require up to 45ºC or 108ºF and then touch the START button This takes you back to the main operating screen where you can now start the PUMP and the SYSTEM as usual The status bar on the front of the unit will turn RED when you touch the START button to indicate that your iCool is now heating It will continue to heat until it reaches your pre set temperature and then hold that tempe...

Page 8: ...fety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is required to prevent the system from changing modes accidentally See setting up heating mode on page 8 Fan Speeds During normal operation the main fan may automatically change speeds as required to maintain the highest effi...

Page 9: ...se this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the sound level from the screen Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to control the fan speed to give the ver...

Page 10: ...t mode Temperature Limitations Because of the dangers of hypothermia in the case of an unattended athlete using the pool your system will not allow you to set temperatures below 5 C 40 F If the model you are using is the contrast model which also provides heating for contrast therapy you cannot set the temperature above 45 C 112 F because of the risk of scalding These temperature limits have been ...

Page 11: ...eeze due to data or software conflicts Your iCool has 2 computers that monitor and communicate with each other Occasionally a data error can cause them to stop communicating We have designed the system to be as fail safe as possible In most cases if the screen freezes the main computer will still carry on running the system and monitoring the safety features but you will not be able to change anyt...

Page 12: ...ectronic systems occasionally have problems especially in portable systems that have a relatively hard life and where water and heat are involved Fortunately we have very few such problems but as an added benefit we have built into all iCool s a complete manual override system that allows your iCool to operate effectively even if parts of the electronics fail for whatever reason We do not publish ...

Page 13: ...ic Ft per Minute 3 Speed 1100 Cubic Ft per Minute 3 Speed 1100 Cubic Ft per Minute Power Plug 3 Pin Heavy Duty 10 AMP Plug 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug Weight Kilos Pounds 40kg 85 Lbs 35kg 79Lbs 36kg 79 Lbs 39kg 85 Lbs Dimensions H W D Millimeters 610w x 630h x 325d 610 x 500 x 240 610 x 500 x 240 610 x 500 x 240 Dimensions H W D Inches 24 x 25 x 12 5 24 x ...

Page 14: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com ...

Reviews: