iCool TWIN Owner'S Manual Download Page 10

DISPLAY 

COUNTDOWN

FULL

SCREEN

shut down automatically and the clock digits on the bottom right of 
the screen will begin to flash as with setting the clock. Use the same 
up down and left right arrows to set the number of hours and minutes 
you wish to elapse before the system automatically shuts down. 
The system automatically begins the countdown and will stop when 
the amount of time you set reaches zero. The time remaining before 
shutdown is displayed on the main clock display screen.

As the same arrows are used to set all three time functions, to avoid 
confusion, a red dot appears next to be button of the function being set.

Recovery Session Timer Functions

A very popular and useful feature of your iCool is the session 
countdown timer. This allows you to accurately control the immersion 
times of athletes and to repeat those times as often as needed. This 
is an essential part of successful cryo recovery therapy and is just as 
important as maintaining accurate and consistent temperatures, which 
of course your iCool does perfectly.

The session timer is set up from the main time setting screen by 
touching the set countdown button. The numbers on the setting screen 
in the bottom right-hand corner will begin to flash and you can use 
the left, right and up, down arrows to change the time in minutes and 
seconds. Once you have set the time you want your athletes to remain 
in the bath, touching the display countdown full-screen button will take 
you to the screen illustrated below. This screen allows you to see the 
countdown from a distance and also to control it in various convenient 
ways. The current pool temperature and the outside temperature will 
also be displayed.

The count down can be set for either once only, or it can repeat 
automatically as many times as you like. This is particularly convenient 
if you have a number of athletes using the same pool at the same time. 

The system beeps for each of the last five seconds at the end of each 

countdown to warn the athletes to get ready to get either in or out of the 
pool and pauses for several seconds to allow the changeover before the 
countdown begins again (if it is set in the repeat mode).

Temperature Limitations

Because of the dangers of hypothermia in the case of an unattended 
athlete using the pool, your system will not allow you to set temperatures 

below  5°C/40°F.  If  the  model  you  are  using  is  the  contrast  model 

which also provides heating for contrast therapy you cannot set the 

temperature above 45°C/112°F because of the risk of scalding. These 

temperature limits have been set after wide consultation with the 

sporting industry around the world. There are no demonstrated benefits 

in using water temperature lower than 5°C or above 45°C and therefore 

the risk of doing so is not justified. If you really do need lower or higher 

temperatures for any reason, iCool can change the software on request, 

but this modification is at the owner’s risk.

Timing Functions

Your iCool offers a number of very useful timing 
functions including a real-time clock, a countdown 
timer to time recovery and training sessions and a 
timer to shut down the system automatically at a 
predetermined time after use.  To set up and use 
these functions touch the timer function button 
on the home screen.  You can reach this screen by 
using the back 1 button or the home button.

You can display the time of day on the built-in clock.  

To set the clock touch the set main clock button 
on the timing functions screen and the time setting 

display on the bottom right of the screen will begin flashing. You must 
set it while one of the numbers is flashing by using the up down and 
left right keys. Once you stop using these keys for more than a few 
seconds  the display will stop flashing and the time showing is set into 
the system and the clock begins operating.

The iCool clock operates in the universal 24-hour time style.

Automatic System Shutdown Timer  

BE AWARE THAT THE TWIN MUST SET BOTH SCREENS TO SHUT 
DOWN COMPLETELY

You  can preset your iCool TWIN to shut down 

either of the 2 systems at any time up to five hours 

in the future. This is very convenient for coaches 
and specialists who may want to leave the training 
area early but want to make sure that the system is 
not left running needlessly. To set this time, touch 
the set shut down button on the side you want to 

11

Owner’s manual for iCool Recovery Systems

TIMER FUNCTIONS

SET COUNT DOWN

DISPLAY COUNTDOWN

TIMER FUNCTIONS

DOWN

UP

RIGHT

LEFT

SET SHUT DOWN

SET MAIN CLOCK

Time Setting Screen

11:25

Summary of Contents for TWIN

Page 1: ...Owners Manual iCool TWIN ...

Page 2: ...olled heating Now you can provide advanced contrast therapy sessions at a much lower cost The Twin can provide any temperature used in recovery therapy into 2 pools at the same time One can be hot and one cold or both cold and all temperatures are accurately and automatically maintained The TWIN is the perfect solution for a world class recovery centre at an affordable price in fact the lowest pri...

Page 3: ...ugh your iCool is produced by a high quality long life circulating pump that includes an effective filter system to keep the pool water clean The pump with your iCool can not begin to operate correctly unless it is fed with a head of water from a pool therefore the level of water in the pool must be higher than the pump and any air tapped in the feeding hoses must be removed There must be no air t...

Page 4: ...in 4 3 Connect 5 to the bottom of the pool 2 To operate 2 pools simply repeat the illustration for the second pool STEP 1 2 QUICK START GUIDE The following is a quick start guide to get your iCool up and running quickly however you should read the entire manual to get the most out of your iCool WARNING The water level in the pool must be above the water inlet of the pump or the pump can not start ...

Page 5: ...anner It also provides a substantial amount of additional information to assist you When you turn on the power for the first time the system will load the latest software from its memory and run a diagnostic self test routine This will take about 20 seconds During this time you will see this screen shown at right and then a BLACK screen The System Status Bars will flash white The STATUS BARS on ea...

Page 6: ...r iCool is ready to use The Status bars glow BLUE when only the pump is running GREEN when the cooling system is running and RED when the heating system is running If the bars glow RED when you try to start cooling please refer to page 7 for an explanation Your twin is actually 2 separate iCool machines so they can be operated completely independently from each other If you only want to use one sy...

Page 7: ...mperature you require up to 45ºC or 108ºF and then touch the START button This takes you back to the main operating screen where you can now start the PUMP and the SYSTEM as usual The status bar on the front of the unit will turn RED when you touch the START button to indicate that your iCool is now heating It will continue to heat until it reaches your pre set temperature and then hold that tempe...

Page 8: ...fety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is required to prevent the system from changing modes accidentally See setting up heating mode on page 8 Fan Speeds During normal operation the main fan may automatically change speeds as required to maintain the highest effi...

Page 9: ...se this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the sound level from the screen Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to control the fan speed to give the ver...

Page 10: ...t mode Temperature Limitations Because of the dangers of hypothermia in the case of an unattended athlete using the pool your system will not allow you to set temperatures below 5 C 40 F If the model you are using is the contrast model which also provides heating for contrast therapy you cannot set the temperature above 45 C 112 F because of the risk of scalding These temperature limits have been ...

Page 11: ...eeze due to data or software conflicts Your iCool has 2 computers that monitor and communicate with each other Occasionally a data error can cause them to stop communicating We have designed the system to be as fail safe as possible In most cases if the screen freezes the main computer will still carry on running the system and monitoring the safety features but you will not be able to change anyt...

Page 12: ...ectronic systems occasionally have problems especially in portable systems that have a relatively hard life and where water and heat are involved Fortunately we have very few such problems but as an added benefit we have built into all iCool s a complete manual override system that allows your iCool to operate effectively even if parts of the electronics fail for whatever reason We do not publish ...

Page 13: ...ic Ft per Minute 3 Speed 1100 Cubic Ft per Minute 3 Speed 1100 Cubic Ft per Minute Power Plug 3 Pin Heavy Duty 10 AMP Plug 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug Weight Kilos Pounds 40kg 85 Lbs 35kg 79Lbs 36kg 79 Lbs 39kg 85 Lbs Dimensions H W D Millimeters 610w x 630h x 325d 610 x 500 x 240 610 x 500 x 240 610 x 500 x 240 Dimensions H W D Inches 24 x 25 x 12 5 24 x ...

Page 14: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com ...

Reviews: