Owner’s manual for iCool Recovery Systems

STEP 5

Touch the start pump button. This will start the pump operating and 
water should begin circulating. 

NOTE: When you touch START buttons they change to STOP buttons 
and can then be used to STOP that function if required.

It is essential that the water is flowing correctly before you touch the 
start system button. The water flow is pre set to an optimum flow rate. 
This allows time for the heat exchangers to operate at maximum cooling 

efficiency. Pool water is completely changed approximately every 15 to 

20 minutes. Do not touch the start system button until you are sure 
that water is flowing smoothly. If water does not flow smoothly within 
a minute or so, please check that the hose with the pump  is flat on the 
floor and no part of it is higher than the top of the water. Check that the 
water in the pool is higher than the pump. If this does not correct the 
problem the system will sound an alarm and a red warning screen will 
appear with information about how to correct the water flow problem.

Main Operating Screen

Personal Logo Screens

Water Temperature Setting Screen

While the software is loading the status bars will flash white, the screen 
shown above will be seen, then a black screen appears for about 15 
seconds while the computers test the safety systems.

After the self test is completed, your personal logo screen or a standard 
WELCOME screen will appear. Touching each screen anywhere will 
stop the bars flashing and show a steady white light to indicate that the 
systems checks were successful and that your iCool is ready to use.

The Status bars glow BLUE when only the pump is running, GREEN  
when the cooling system is running and RED when the heating system 
is running.

If the bars glow RED when you try to start cooling please refer to page 
7 for an explanation.      

   

Your twin is actually 2 separate iCool machines, so they can be operated 
completely independently from each other. If you only want to use one 
system, just ignore the other one, it will do no harm. Just touch the 
screen of the unused one to stop the status light flashing.

If you ordered a personal logo screen your WELCOME screen will 
look like the samples (right). Otherwise the standard iCool welcome 
screen will appear. Touch your logo or welcome screen anywhere to 
continue.

The Main Operating Screen will now appear

The main operating screen provides many options which are covered 
elsewhere in this manual, however to quickly start the system you 
can simply accept the default water temperature setting of 15ºC or,  
to select a different temperature touch the CHANGE settings button. 
Then 10ºC will be inserted automatically, but you can change to any 
temperature you require at this point. Simply touch the up and down 
arrow buttons and the desired pool water temperature will appear on 
the bottom left-hand of the screen in the blue window marked  “selected 
temperature”.  The right-hand side of the screen shows the outside air 
temperature. The temperatures is in degrees centigrade, however it can 
also be displayed in Fahrenheit. This is explained later in this Manual.

Once you have selected the pool water temperature you want for each 
pool, touch the start buttons on each screen. This takes you back to the 
main run screen which is the screen that you will use most of the time 
during normal operation.

15

°

24

°

10

°

22

°

30

°

22

°

Summary of Contents for TWIN

Page 1: ...Owners Manual iCool TWIN ...

Page 2: ...olled heating Now you can provide advanced contrast therapy sessions at a much lower cost The Twin can provide any temperature used in recovery therapy into 2 pools at the same time One can be hot and one cold or both cold and all temperatures are accurately and automatically maintained The TWIN is the perfect solution for a world class recovery centre at an affordable price in fact the lowest pri...

Page 3: ...ugh your iCool is produced by a high quality long life circulating pump that includes an effective filter system to keep the pool water clean The pump with your iCool can not begin to operate correctly unless it is fed with a head of water from a pool therefore the level of water in the pool must be higher than the pump and any air tapped in the feeding hoses must be removed There must be no air t...

Page 4: ...in 4 3 Connect 5 to the bottom of the pool 2 To operate 2 pools simply repeat the illustration for the second pool STEP 1 2 QUICK START GUIDE The following is a quick start guide to get your iCool up and running quickly however you should read the entire manual to get the most out of your iCool WARNING The water level in the pool must be above the water inlet of the pump or the pump can not start ...

Page 5: ...anner It also provides a substantial amount of additional information to assist you When you turn on the power for the first time the system will load the latest software from its memory and run a diagnostic self test routine This will take about 20 seconds During this time you will see this screen shown at right and then a BLACK screen The System Status Bars will flash white The STATUS BARS on ea...

Page 6: ...r iCool is ready to use The Status bars glow BLUE when only the pump is running GREEN when the cooling system is running and RED when the heating system is running If the bars glow RED when you try to start cooling please refer to page 7 for an explanation Your twin is actually 2 separate iCool machines so they can be operated completely independently from each other If you only want to use one sy...

Page 7: ...mperature you require up to 45ºC or 108ºF and then touch the START button This takes you back to the main operating screen where you can now start the PUMP and the SYSTEM as usual The status bar on the front of the unit will turn RED when you touch the START button to indicate that your iCool is now heating It will continue to heat until it reaches your pre set temperature and then hold that tempe...

Page 8: ...fety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is required to prevent the system from changing modes accidentally See setting up heating mode on page 8 Fan Speeds During normal operation the main fan may automatically change speeds as required to maintain the highest effi...

Page 9: ...se this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the sound level from the screen Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to control the fan speed to give the ver...

Page 10: ...t mode Temperature Limitations Because of the dangers of hypothermia in the case of an unattended athlete using the pool your system will not allow you to set temperatures below 5 C 40 F If the model you are using is the contrast model which also provides heating for contrast therapy you cannot set the temperature above 45 C 112 F because of the risk of scalding These temperature limits have been ...

Page 11: ...eeze due to data or software conflicts Your iCool has 2 computers that monitor and communicate with each other Occasionally a data error can cause them to stop communicating We have designed the system to be as fail safe as possible In most cases if the screen freezes the main computer will still carry on running the system and monitoring the safety features but you will not be able to change anyt...

Page 12: ...ectronic systems occasionally have problems especially in portable systems that have a relatively hard life and where water and heat are involved Fortunately we have very few such problems but as an added benefit we have built into all iCool s a complete manual override system that allows your iCool to operate effectively even if parts of the electronics fail for whatever reason We do not publish ...

Page 13: ...ic Ft per Minute 3 Speed 1100 Cubic Ft per Minute 3 Speed 1100 Cubic Ft per Minute Power Plug 3 Pin Heavy Duty 10 AMP Plug 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug Weight Kilos Pounds 40kg 85 Lbs 35kg 79Lbs 36kg 79 Lbs 39kg 85 Lbs Dimensions H W D Millimeters 610w x 630h x 325d 610 x 500 x 240 610 x 500 x 240 610 x 500 x 240 Dimensions H W D Inches 24 x 25 x 12 5 24 x ...

Page 14: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com ...