Correct Sensor Position Setup
TI Series flow meters measure liquid media only. There should
be no air bubbles and the pipe must always remain full. To ensure
accurate flow measurement, the placement of the flow meter
needs to adhere to specific parameters. This requires a straight run
pipe with a minimum number of pipe diameters distance upstream
and downstream of the flow sensor.
Installation Positions
Flange
90º Downward Flow
2x 90º Elbow
90º Elbow Flow Upward
Reducer
Ball Valve
Figure - 1
Figure - 2
Figure - 3
Good if NO SEDIMENT present
*NOTE: Maximum % of solids ≤ 10% with particle size not exceeding 0.5mm cross section or length.
Good if NO AIR BUBBLES present
Preferred installation if
SEDIMENT* or AIR BUBBLES
may be present
TIF Series
Multi-Function Batching Paddle Wheel Flow Meter