background image

Warranty, Returns and Limitations

Warranty

Icon Process Controls Ltd

 warrants to the original purchaser of its products that such products will be free from defects in  

material and workmanship under normal use and service in accordance with instructions furnished by 

Icon Process Controls Ltd

 

for a period of one year from the date of sale of such products. 

Icon Process Controls Ltd

 obligation under this warranty is solely 

and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which 

Icon Process Controls Ltd

  examination determines to its satisfaction to be defective in material or workmanship within the  

warranty period. 

Icon Process Controls Ltd

 must be notified pursuant to the instructions below of any claim under this warranty 

within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be  

warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will 

be warranted for the one year from the date of replacement.

Returns

Products cannot be returned to 

Icon Process Controls Ltd

 without prior authorization. To return a product that is thought to be 

defective, go to www.iconprocon.com, and submit a customer return (MRA) request form and follow the instructions therein. All 

warranty and non-warranty product returns to 

Icon Process Controls Ltd

 must be shipped prepaid and insured. 

Icon Process 

Controls Ltd

 will not be responsible for any products lost or damaged in shipment.

Limitations

This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original  

purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical 

damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel 

authorized by 

Icon Process Controls Ltd

 have attempted to repair; 5) have been involved in accidents or natural disasters; or  

6) are damaged during return shipment to 

Icon Process Controls Ltd

 reserves the right to unilaterally waive this warranty and  

dispose of any product returned to 

Icon Process Controls Ltd

 where: 1) there is evidence of a potentially hazardous material  

present with the product; or 2) the product has remained unclaimed at 

Icon Process Controls Ltd

 for more than 30 days after 

Icon Process Controls Ltd

 has dutifully requested disposition. This warranty contains the sole express warranty made by 

Icon 

Process Controls Ltd

 in connection with its products. 

ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED

. The  

remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. 

IN NO EVENT 

SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND I 

NCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, 

COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER 

WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd

. This warranty will be interpreted pursuant to 

the laws of the province of Ontario, Canada.

If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other 

 

provision of this warranty.

For additional product documentation and technical support visit:

www.iconprocon.com   |   e-mail: [email protected] or suppor[email protected]   |   Ph: 905.469.9283

TIF Series

Multi-Function Batching Paddle Wheel Flow Meter

9

23-0069

Summary of Contents for truflo TIF Series

Page 1: ...ent changes without prior notice Rotates 330 M12 Quick Connect M12 Keyed to Ensure Proper Connection Vibrant 2x 6 Digit LED Display Corrosion Resistant NEMA 4X Enclosure Simple Push button Programming True Union Design TIF Series Multi Function Batching Paddle Wheel Flow Meter 1 23 0069 ...

Page 2: ...during installation and service of Truflo products Pressurized System Warning Sensor may be under pressure Take caution to vent system prior to installation or removal Failure to do so may result in equipment damage and or serious injury WARNING General Information Function Description Specification Operating Voltage 10 30VDC Current Compensation 60mA max Control Communication RS 485 Modbus Transm...

Page 3: ...read of the sensor cap then turn the sensor until the alignment tab is seated in the fitting notch Ensure tab is parallel to flow direction Hand tighten DO NOT use tools Ensure meter is firmly in place Installation Very Important Lubricate O rings with silicone provided Using an alternating twisting motion carefully lower the sensor into the fitting Do Not Force See Fig 5 Ensure tab notch are para...

Page 4: ...minimum number of pipe diameters distance upstream and downstream of the flow sensor Installation Positions Flange 90º Downward Flow 2x 90º Elbow 90º Elbow Flow Upward Reducer Ball Valve Figure 1 Figure 2 Figure 3 Good if NO SEDIMENT present NOTE Maximum of solids 10 with particle size not exceeding 0 5mm cross section or length Good if NO AIR BUBBLES present Preferred installation if SEDIMENT or ...

Page 5: ...tor Combo 220 200 180 160 140 120 100 80 60 40 20 0 60 PVC PP PVDF 104 140 175 212 248 20 F C 40 60 80 100 120 15 2 psi bar 13 8 12 4 11 0 9 7 8 3 6 9 5 5 4 1 2 8 1 4 0 Note During system design the specifications of all components must be considered Non Shock The TIF Series is equipped with a zirconium ceramic rotor pin and 2 bushings The TIF Series also incorporates a contoured Low Drag paddle w...

Page 6: ...t Value of Flow Rate Change to a Value that meets your Flow Rate Pulse Output SV CV SV Flow Rate Pulse Output ON CV SV Flow Rate Pulse Output OFF CV Program Value of Flow Totalizer Pulse NPN Output SV Preset Value of Flow Total SV CV SV Flow Rate Pulse Output ON 2000 Default can be changed to desired value Refer to Programming OP2 Output for totalizer options Flow Totalizer Pulse Step 2 Next Trans...

Page 7: ... and Hold SET 1 3 Sec ALT NO Description ALt 0 CV SV ON CV SV HyS OFF Normally Closed Relay ALt 1 CV SV ON CV SV HyS OFF Normally Open Relay ALt 2 SV HyS CV SV HyS ON CV SV HyS or CV SV HyS OFF ALt 3 SV HyS CV SV HyS OFF CV SV HyS or CV SV HyS ON HyS Hysteresis Acts like a buffer around pulse output measured in GPM CV Current Value Flow Rate SV Selected or Programmed Value PIPE SIZE GPM LPM DN15 1...

Page 8: ...rox 50 07 GENTLY tap 08 Congratulations Replacement procedure is complete 09 Ensure holes are aligned Pull out 05 Insert new paddle in flow meter 06 GENTLY tap 02 Tap until pin is 50 out 02 Small Pin Paddle Pin Hole TIF Series Multi Function Batching Paddle Wheel Flow Meter 8 23 0069 ...

Page 9: ...ve 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair 5 have been involved in accidents or natural disasters or 6 are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilat...

Reviews: