![Icom M506 31 Instruction Manual Download Page 79](http://html1.mh-extra.com/html/icom/m506-31/m506-31_instruction-manual_4733739079.webp)
70
7
DSC OPERATION
New2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
D
DSC Data Output
Select an option for the DSC Data Output function.
When receiving a DSC call, this function makes the trans-
ceiver send the DSC data from its NMEA Output port to a
connected device.
q
Enter “DSC DATA OUTPUT” in the DSC Settings menu.
MENU
➪
DSC SET
➪
DSC Data Output
(Push [MENU]) (Select icon) (Rotate dial, then push [ENT].)
w
Rotate dial to set the DSC Data Output function to “All Sta-
tion,” “List Station” or “OFF,” then push [ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
(default)
All Stations: Outputs the call from any vessel from the
NMEA Output port.
Station List: Outputs the call from any vessels listed on the
Individual ID screen.
OFF:
Does not output any call to the external equip-
ment.
Push [EXIT] to return to the normal operating mode.
e
D
Alarm Status
Set the Alarm function ON or OFF, depending on the Cat-
egory or Status.
q
Enter “ALARM STATUS” in the DSC Settings menu.
MENU
➪
DSC SET
➪
Alarm
(Push [MENU]) (Select icon) (Rotate dial, then push [ENT].)
w
Rotate dial to select the status, then push [ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
• “ Safety,” “Routine,” “Warning,” “Self-Terminate” and “Discrete” are
selectable.
(default: ON)
Rotate dial to set the Alarm setting to “ON” or “OFF.”
e
Push [EXIT] to return to the normal operating mode.
r