background image

ADJUSTMENT 

Adjustment          No.        Adjustment Condition & Tuning                      Value      Ref. No. CK. Point  

Checking RX               Check that the signal generator level is as    

Sensitivity              follows when the distortion meter shows  

12 dB  SINAD in the range of  

frequency coverage. 

  RX Sensitivity     Less than -10 dBu         Less-10dB                ANT Con 

                                                                                                                                     SP Jack     

                                Use the same check method for Narrow  

                                channels also. 

                  

Adjusting the           This Adjustment should be perform after the   

S3 LEVEL                   RX sensitivity adjustment finished. 

                

                 Set the signal generator following setting  

                                for wide channels. 

               

                                        Adjust Freq.              Near 136 MHz        

                                       SG Input level           +23 dBu 

                                        Modulation Freq.          1kHz 

                                                 WIDE                  ± 3.5 kHz 

                                   

                      S3 SET COMMAND with the Adjustment soft 

Adj.Soft                ANT Con 

                                   ware.                                                                      S-METER

 

                                                                                                         S3 Level  

Adjusting the              

Set the signal generator level to  the 

S1 LEVEL                    following value.                                                            

 

                                         SG Output Level            -7 dBu 

 

                      S1 SET COMMAND with the Adjustment soft 

Adj.Soft                ANT Con

 

                                   ware.                                                                     S-METER

 

                                                                                                        

S1 Level

 

                                                                                                 

 

                                                                                                          

 

 

 

 

 

 

 

 

Summary of Contents for IC-F520

Page 1: ...RX C134 during TX Adj Freq 136 MHz RX Side 1 4V 1 4V C133 LV TX Side 1 0V 1 0V C134 Lock Voltage Set the transceiver to the 174 MHz Check and check that each value is within following values Adj Freq...

Page 2: ...20 0 30 0W 20 30W ANT Con L2 Power 8 0 12 5W 8 12 5W L1 Power 2 0 3 0W 2 0 3 0W Current Check at Check that the Hi Power current is less than TX the following value in the range of frequency coverage...

Page 3: ...Connect a millivolt meter or a 600 ohm out put impedance CR oscillator to the trans ceiver s mic terminal Modulation Use the adjustment software to adjust the Balance modulation analyzer s detection o...

Page 4: ...ent to the antenna terminal Set the transceiver to wide ch and CTCSS 88 5Hz Transmit the transceiver with no input to the mic or mic terminal Adjust Freq Near Center Frequency Adj Soft ANT Con WIDE 0...

Page 5: ...ssible deviation Check that the TX S N in the range of the Frequency coverage is more than the following values WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB Adjusting RX dur...

Page 6: ...rrow channels also Adjusting the This Adjustment should be perform after the S3 LEVEL RX sensitivity adjustment finished Set the signal generator following setting for wide channels Adjust Freq Near 1...

Page 7: ...In this condition using the adjustment Adj Soft software raise the squelch D A value until SQL the squelch closes once then lower the D A value again and adjust until the squelch opening point Checki...

Page 8: ...that the AF output reaches 50 of the rated value Check that the RX S N in the range of frequency is as following values WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB SP Jack...

Reviews: