background image

ADJUSTMENT 

Adjustment          No.        Adjustment Condition & Tuning                     Value       Ref. No. CK. Point  

Adjusting the           turn the transceiver to the narrow channel   

Squelch                     at center frequency. 

 

                                Set the signal generator to as following. 

                                                                                                                                    ANT Con 

 

                                        Modulation Freq.              1kHz 

                                                  WIDE                   ± 3.5 kHz 

                                                 NARROW                 ± 1.75 kHz 

                                         SG Output Level            -14 dBu 

 

                                In this condition, using the adjustment                        Adj.Soft 

                                software, raise the squelch D/A value until                   SQL 

                                the squelch closes once, then lower the D/A 

                                value again, and adjust until the squelch  

                                opening point. 

 

Checking Squelch       Check that the squelch opening point value 

Sensitivity              in the range of frequency condition  

is as follows. 

                         

                                       Squelch Sensitivity  Less than –10 dBu     Less-10dB               ANT Con     

                          

                                Next, reduce the signal generator output  

                                and check that the squelch closes 

                                in the range of frequency condition. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IC-F520

Page 1: ...RX C134 during TX Adj Freq 136 MHz RX Side 1 4V 1 4V C133 LV TX Side 1 0V 1 0V C134 Lock Voltage Set the transceiver to the 174 MHz Check and check that each value is within following values Adj Freq...

Page 2: ...20 0 30 0W 20 30W ANT Con L2 Power 8 0 12 5W 8 12 5W L1 Power 2 0 3 0W 2 0 3 0W Current Check at Check that the Hi Power current is less than TX the following value in the range of frequency coverage...

Page 3: ...Connect a millivolt meter or a 600 ohm out put impedance CR oscillator to the trans ceiver s mic terminal Modulation Use the adjustment software to adjust the Balance modulation analyzer s detection o...

Page 4: ...ent to the antenna terminal Set the transceiver to wide ch and CTCSS 88 5Hz Transmit the transceiver with no input to the mic or mic terminal Adjust Freq Near Center Frequency Adj Soft ANT Con WIDE 0...

Page 5: ...ssible deviation Check that the TX S N in the range of the Frequency coverage is more than the following values WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB Adjusting RX dur...

Page 6: ...rrow channels also Adjusting the This Adjustment should be perform after the S3 LEVEL RX sensitivity adjustment finished Set the signal generator following setting for wide channels Adjust Freq Near 1...

Page 7: ...In this condition using the adjustment Adj Soft software raise the squelch D A value until SQL the squelch closes once then lower the D A value again and adjust until the squelch opening point Checki...

Page 8: ...that the AF output reaches 50 of the rated value Check that the RX S N in the range of frequency is as following values WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB SP Jack...

Reviews: