background image

ADJUSTMENT 

Adjustment          No.        Adjustment Condition & Tuning                     Value      Ref. No. CK. Point  

Checking                   Set the signal generator output level to  

 AF Output     

        +60 dBu. The transceiver and SG connection 

                                is the same as the squelch adjustment above. 

                                Adjust the transceiver volume until the  

                                distortion meter reads 5%. 

                                Check that the AF output value at this point 

                                Is as below. 

                                                                                                         Over                      ANT Con 

  AF Output               More than 3.5 W           3.5 W                      SP Jack 

                                                                                                       @ 4 ohm 

                                                                                                         load 

 

Checking RX S/N        Set the signal generator output level to 

                                +60 dBu. Adjust the AF volume so that the 

                                AF output reaches 50% of the rated value.  

                                Check that the RX S/N in the range of  

frequency  is as following values. 

                          

                                              WIDE               More than 40 dB            Over 40dB                ANT Con 

       NARROW              More than 34 dB            Over 34dB                SP Jack 

                           

Checking                   Set the signal generator output to +60 dBu 

Howling                     as in RX adjustment with no deviation.            ANT Con 

                                set the internal speaker for operation,                                       Int SP 

                                and turn the AF volume up to maximum to 

                                check that howling does not occur. 

 

Checking                   While still in the AF output check status, 

Maximum                     rotate the volume control clockwise to  

RX Current                obtain the maximum AF output. Check that the  

current consumption at this time is as the 

following value. 

        

                                        Max. RX Current       Less than 1200 mA     Less than                PWR Con     

                                                                                                        1200mA 

                 

 

 

 

 

Summary of Contents for IC-F520

Page 1: ...RX C134 during TX Adj Freq 136 MHz RX Side 1 4V 1 4V C133 LV TX Side 1 0V 1 0V C134 Lock Voltage Set the transceiver to the 174 MHz Check and check that each value is within following values Adj Freq...

Page 2: ...20 0 30 0W 20 30W ANT Con L2 Power 8 0 12 5W 8 12 5W L1 Power 2 0 3 0W 2 0 3 0W Current Check at Check that the Hi Power current is less than TX the following value in the range of frequency coverage...

Page 3: ...Connect a millivolt meter or a 600 ohm out put impedance CR oscillator to the trans ceiver s mic terminal Modulation Use the adjustment software to adjust the Balance modulation analyzer s detection o...

Page 4: ...ent to the antenna terminal Set the transceiver to wide ch and CTCSS 88 5Hz Transmit the transceiver with no input to the mic or mic terminal Adjust Freq Near Center Frequency Adj Soft ANT Con WIDE 0...

Page 5: ...ssible deviation Check that the TX S N in the range of the Frequency coverage is more than the following values WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB Adjusting RX dur...

Page 6: ...rrow channels also Adjusting the This Adjustment should be perform after the S3 LEVEL RX sensitivity adjustment finished Set the signal generator following setting for wide channels Adjust Freq Near 1...

Page 7: ...In this condition using the adjustment Adj Soft software raise the squelch D A value until SQL the squelch closes once then lower the D A value again and adjust until the squelch opening point Checki...

Page 8: ...that the AF output reaches 50 of the rated value Check that the RX S N in the range of frequency is as following values WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB SP Jack...

Reviews: