4 - 10
ADJUSTMENT ITEM
TRANSCEIVER'S
CONDITION
OPERATION
MEASURE
POINT
ADJUST
POINT
VALUE
PREPARATION
–
• Connect an SSG to [ANT1], and
then set it as;
Frequency : 14.1515 MHz
Modulation : None
Level :
+20 dBu (–87 dBm)
–
–
–
TOTAL GAIN
ADJUSTMENT
1 • Display: "Total Gain HF POFF"
• Receiving
–
–
–
Push [F-5].
(Beeps sound
12 sec. later)
2 • Display: "Total Gain HF PON"
• Receiving
–
–
–
Push [F-5].
(Beeps sound
12 sec. later)
EXTERNAL AGC
3 • Display: "AGC (HF)"
• Receiving
• Set the SSG as;
Level :
+70 dBu (–37 dBm)
–
–
Push [F-5].
(Beeps sound
22 sec. later)
S-METER
NOTE: DO NOT
change the output level of the SSG until the beep sounds.
4 • Display: "S0 Level HF"
• Receiving
• Set the SSG as;
Level
: OFF
–
–
Push [F-5].
(Beep sounds,
and then anoter
beep sounds
0.5 sec. later)
5 • Display: "S9 Level HF"
• Receiving
• Set the SSG as;
Level :
+34 dBu (–73 dBm)
Push [F-5].
(Beep sounds,
and then anoter
beep sounds
1 sec. later)
6 • Display: "S9+60 Level HF"
• Receiving
• Set the SSG as;
Level :
+90 dBu (–17 dBm)
Automatically returns to the receive adjustment menu.
¤
RECEIVE ADJUSTMENTS
MENU
H F
RX
Reterns to the previous screen.
Stores the value and move to the next ite
Starts the receiveadjustment.