background image

 

 

 

 

 

 

 

IGS-700 

 

DVB-S2 Quad-Receiver IP-Streamer 

 

 

 

 

 

 

 

 

 

Datasheet & Instruction Manual 

V1.1 

Summary of Contents for IGS-700

Page 1: ...IGS 700 DVB S2 Quad Receiver IP Streamer Datasheet Instruction Manual V1 1 ...

Page 2: ...tent 2 Introduction 3 Features 4 Technical Data 4 Hardware 5 Installation 5 Let s start with the Web Interface 6 IP Streaming Port settings 8 Input configuration 9 CI Modules 11 BISS decryption menu 12 TS Configuration 12 SPTS Menu 13 SYSTEM settings 15 SETUP by using the Front Panel 16 Important Notes 20 ...

Page 3: ... the capacity of the inserted CAM s 4 Tuner Inputs DVB S S2 o DVB C DVB T T2 optional available as dual frontends can be mixed 2x2 1 ASI 4 MPTS IP UDP via GbE RJ45 Inputs 4x CAM s for Multi Service Decryption from RF ASI IP IP 48 SPTS 4 MPTS streaming output as UDP or RTP RTSP CBR VBR support Null Packet Filter selectable CA Flag Filter as well 4x dual ASI outputs for Tuner IP pass through mode Su...

Page 4: ...put Monitoring Configuration Ethernet Format Power supply Mains voltage Power consumption General Dimensions W H D mm Weight 18 dB 188 Byte 204 Byte 1x IP GbE Interface for IP I O UDP Uni and Multicast RTP RTSP MPTS SPTS IP streaming inputs MPTS and up to 48 SPTS 4 x DVB CI slot CAM DVB CI compliant CA systems with professional CAM Viaccess Conax Irdeto Seca Mediaguard Nagravision No CI support 4x...

Page 5: ...nput to another RF Input please consider that only the first one in a serial looping should be configured to serve the multiswitch with 13 18V 22KHz DiSEqC signals Disadvantage is logical The following and looped RF Inputs can only make use of the same SAT parameters as used for the first one Example RF IN 1 is set to High band Horizontal and DiSEqC used SAT 2 18V 22kHz DiSEqC 2 The looped next In...

Page 6: ...ernet for streaming in and out NMS Management port and SNMP port for the Web IF PSU Power supply C14 inlet connector with ON OFF switch Grounding connector Please use this to establish ground earth contact with your electrical installations according to international norms and rules If a central grounding is used in a 19 Rack please connect the unit to it accordingly Let s start with the Web Inter...

Page 7: ...eT for the Management NMS RJ45 port and a second Gigabit Ethernet 10 100 1000BaseT with at least Layer 2 with IGMP V2 features Otherwise you might flood your IP Streaming network with unnecessary Data which might overload connected IPTV STB s because they almost have only 100BaseT capacity If you need to select a Switch we recommend HP Procurve 2530 24G or 48G which are cost effective easy to conf...

Page 8: ...IGS 700 User Manual Author RRi 8 Date 05 Jun 2017 IGS 700 docx Version 1 1 IP Streaming Port settings Set your output stream destinations multicast or unicast addresses and Port No scroll down up to ...

Page 9: ...icast blocking setup methods to avoid flooding The reason why the streaming port definitely needs an IP address is simple W o any obligatory IP Address the connected network would not be aware of this port Also it s mandatory if you want to stream in Unicast mode Destination and Sender must be defined properly Select streaming mode UDP or RTP RTSP We skip an explanation of these protocols Please G...

Page 10: ...If using splitters we recommend to serve the Multiswitch with power 22KHz just by one of the combined Input RF ports The other ones should be set to 0V and no 22KHz incoming ASI and Bit rate will be shown Same for a received MPTS from the GbEthernet DATA Input port We recommend switching IGMP to ON The version should harmonize with your used GbE Switch Layer 2 or better UDP or RTP can be chosen as...

Page 11: ...se the latest software hardware version Note There are Consumer CAM s and professional CAM s on the market Consumer CAM s often can only decrypt up to 2 TV Services The CA module diversity of other manufactures is increasing permanently the using of them might be possible but BLANKOM IRENIS is not able to guarantee for faultless operating in all cases Because there are so many good and bad CI modu...

Page 12: ... need to be considered with at least a recommended overhead of 10 15 null packet insertion PID 8919 dec to not disturb all TV Radio Services in a stream if the peaks of the cumulated services would exceed the configured Megabit per second ASI can be used up to 213 Mbps but that s slightly too much for the GbE output if using all 4 to this So balancing and considering the physical limits should be ...

Page 13: ... by step to be able to select the appropriate services Select chose CA filter and or PID remapper and enable them to swap it to the right window Once the configured and selected Inputs are shown on the left you need to select each Input TS in particular and execute Parse program to read in the services and PID s of each Input ...

Page 14: ...onfigure the MPTS and SPTS you want to stream bitrate setting should calculated and set when CBR w o null packet filter should be streamed Remark NIT and EIT EPG will not be processed by this simple remultiplexing functions Same for single PID Filtering not supported There are some external tools for some models available Just ask please ...

Page 15: ...e 05 Jun 2017 IGS 700 docx Version 1 1 SYSTEM settings Keyboard on Front panel can be locked by a password to avoid unauthorized access The usual user PW setting things do not forget it otherwise you need to do factory reset somehow tricky ...

Page 16: ...ch can be configured by the Keypad and the switches ENTER MENU LOCK Key has to be used to lock unlock the front panel keypad using see WEB IF Menu above The LED s showing the Input status Transponder locked or not RED Alarm LED show status if i e a multiplex will exceed its max Data rate DESCRAM 1 4 gives the status about inserted CA Module is in operation LCD gives feedback for temporary actions ...

Page 17: ...Author RRi 17 Date 05 Jun 2017 IGS 700 docx Version 1 1 Use the keypad to navigate Enter to select Sub menu ENTER Key enters into the Sub Menus Tuner Inputs MENU brings you back Enter forward set change by enter arrow keys ...

Page 18: ...IGS 700 User Manual Author RRi 18 Date 05 Jun 2017 IGS 700 docx Version 1 1 CAM s BISS use keys and select by Enter select or arrow keys until ENTER Select Input and mode ...

Page 19: ...IGS 700 User Manual Author RRi 19 Date 05 Jun 2017 IGS 700 docx Version 1 1 ENTER So it s almost self explaining and you will get familiar with the usage very soon ...

Page 20: ...changes in the products described herein at any point of time Installation Notes All types of the IRENIS BLANKOM family are 19 devices with 1 RU height designed for installation in 19 racks In addition to the front panel screws an internal module support is required at the rack Depending on the Frontend used and the operating adjustments the RF input port carries DC Voltage 13V 18V max 400 mA By c...