87
11
SET MODE
2001 NEW
2001 NEW
38.
CI-V Transceive
Transceive operation is possible with the IC-7400
connected to other Icom HF transceivers or receivers.
ON
: Transceive ON (default)
OFF
: Transceive OFF
When “ON” is selected, changing the frequency, op-
erating mode, etc. on the IC-7400 automatically
changes those of connected transceivers (or re-
ceivers) and vice versa.
3 8
O N
C I - V T r a n s c e i v e
39.
CI-V 731 Mode
When connecting the IC-7400 to the IC-735 for trans-
ceive operation, you must change the operating fre-
quency data length to 4 bytes.
• This item must be set to “ON” only when operating the
transceiver with the IC-735.
ON
: 4 bytes of frequency data
OFF
: 5 bytes of frequency data (default)
3 9
O F F
C I - V 7 3 1 M o d e
■
General set mode (continued)
37.
CI-V Address
To distinguish equipment, each CI-V transceiver has
its own Icom standard address in hexadecimal code.
The IC-7400’s address is 66h.
When 2 or more IC-7400’s are connected to an op-
tional CT-17
CI
-
V LEVEL CONVERTER
, rotate the tuning
dial to select a different address for each IC-7400 in
the range 01h to 7Fh.
3 7
6 6 h
C I - V A d d r e s s
36.
CI-V Baud Rate
This item sets the data transfer rate. 300, 1200, 4800,
9600, 19200 bps and “Auto” are available.
Auto
: Auto baud rate (default)
3OO
: 300 bps
12OO
: 1200 bps
48OO
: 4800 bps
96OO
: 9600 bps
192OO
: 19200 bps
When “Auto” is selected, the baud rate is automati-
cally set according to the connected controller or re-
mote controller.
3 6
A u t o
C I - V B a u d R a t e
IC-7400.qxd 02.4.2 11:35 Page 87