15
Explanation of the function button (set by an expert)
4-13: Voltage standard value setting
Measure the voltage at the place of installation and enter the
standard value. This product guarantees
10% of the supply
power. When it is outside of the range a warning sound is given.
If used continually, the product can have problems.
4-14: Button sensitivity setting
This sets button sensitivity.
A smaller number means more sensitivity and a larger number
means less sensitivity.
4-11: Environmental temperature detect function setting
The function to detect the environmental temperature can be turned
ON/OFF. Environmental temperature is the temperature of the air
coming into the compressor. Therefore, the temperature for this
category can be high and a warning message can be given if the
place of installation is small and has no ventilation.
Then the installation environment must be improved.
4-12: No load detection function setting
The no load detection function can be turned ON/OFF.
"No load" means the raw material inside the cylinder exists in a liquid
condition. The motor current is then called "no load current."
If this function is set to on, power is allowed to the product and the no
load current is remembered when the temperature of the cylinder is
higher than 5
)
C.
4-15: Voice language selection
The language set in this category gives voice guidance, and a total
2 languages are embedded.
:Korean, :English
4-16: Set motor current value correction
This is the function for performing overall compensation when the
measured motor current is different from the actual measurement
value.
4-17: Air pump selection
If the model has an air pump, this category can be turned on to
control the operation of the air pump.
1: Operation time setting during the initial operation
Set the operation time of the air pump when beginning initial
operation.