※ The ice maker requires cleaning and sterilizing at least twice a year.
It may need more frequent cleaning and sterilizing.
1. Cleaning solution
Distill scale remover unharmful to human body and increase the ratio as needed.
Distilled cleaning solution must be used immediately to ensure maximum effect and safety.
2. Cleaning procedure
1) Close the water valve to stop water supply.
2) Set the front power switch to 'DRAIN'.
3) Water in the water tank is drained through the evaporator cylinder and cleans it for up to 5 minutes.
4) Set the front power switch to 'OFF' and the switch of the circuit breaker on the back
to 'OFF' as well.
5) Remove all ice from the ice maker and storage bin.
6) Unscrew 5 knob screws from the ice chute assembly and lift up to remove it.
7) Pour the cleaning solution to the extruding head until the evaporator and water reservoir are full.
(Up to the point that the solution overflows from the drip pan)
※ If too much scale at the extruding head clogs the hose between the water reservoir
and the evaporator, fill with cleaning solution until the water reservoir is full
and until the extruding head at the top of the evaporator is fully immersed.
8) Insert the chute baffle assy(l/r) of the ice chute assembly to the inlet of the evaporator
and fix it securely with 4 wing nuts.
9) Leave the ice maker for about 10 minutes before operating the product, and if the water
reservoir hose is clogged in Step 7, make sure to unclog it before starting operation.
10) As with the following description, clean contaminated float level s/w(high, low) by disassembling
the water reservoir. Otherwise, move on to Step 11.
ⓐ Remove the float level s/w from the cover of water reservoir.
ⓑ Clean the sensor with the cleaning solution.
ⓒ Completely rinse the sensor with clean water.
ⓓ Reassemble the sensor back in place.
11) Turn on the circuit breaker and set the power switch to 'ICE' to operate the ice maker.
Operate it until ice making stops
(※ Water will not be supplied as water supply hoses are closed).
12) Set the power switch to 'DRAIN' and drain remaining solution from the water supply
and evaporator cylinder for 5 minutes.
13) Set the front power switch to 'OFF'.
14) Open the valve that locked the water supply hoses and set the power switch to 'ICE' so
that water may be supplied.
15) When the gear motor starts running, set the power switch to 'DRAIN' to drain water for about 5 minutes.
16) Turn off the power switch and circuit breaker and unplug the power cord.
Cleaning / Sterilizing
◆
Make sure to comply with the following.
●
Do not use ammonia-based detergent to prevent damage to the personnel or the ice maker itself.
●
Cleaning and sterilizing must be conducted in accordance with the instructions on the user manual.
●
Always wear protective gloves and goggle to prevent skin or eye from coming into contact
with the sterilizing solution.
●
Do not use the ice made with the cleaning or sterilizing solution after cleaning and sterilizing.
Make sure that no sterilizing solution is left on any part of the ice maker and the ice storage bin.